1926.952 Job Briefing
JUMP TO FULL CODE CHAPTER
In assigning an employee or a group of employees to perform a job, the employer shall provide the employee in charge of the job with all available information that relates to the determination of existing characteristics and conditions required by § 1926.950(d).
The employer shall ensure that the employee in charge conducts a job briefing that meets paragraphs (b), (c), and (d) of this section with the employees involved before they start each job.
The briefing shall cover at least the following subjects: Hazards associated with the job, work procedures involved, special precautions, energy-source controls, and personal protective equipment requirements.
If the work or operations to be performed during the work day or shift are repetitive and similar, at least one job briefing shall be conducted before the start of the first job of each day or shift.
Additional job briefings shall be held if significant changes, which might affect the safety of the employees, occur during the course of the work.
A brief discussion is satisfactory if the work involved is routine and if the employees, by virtue of training and experience, can reasonably be expected to recognize and avoid the hazards involved in the job.
A more extensive discussion shall be conducted:
If the work is complicated or particularly hazardous, or
If the employee cannot be expected to recognize and avoid the hazards involved in the job.
Note to paragraph (d): The briefing must address all the subjects listed in paragraph (b) of this section.
Note to paragraph (d): The briefing must address all the subjects listed in paragraph (b) of this section.
An employee working alone need not conduct a job briefing. However, the employer shall ensure that the tasks to be performed are planned as if a briefing were required.
[75 FR 48135, Aug. 9, 2010; 78 FR 32116, May 29, 2013; 79 FR 20698, July 10, 2014]
[75 FR 48135, Aug. 9, 2010; 78 FR 32116, May 29, 2013; 79 FR 20698, July 10, 2014]
Related Code Sections
1926.952 Electric Power Transmission and Distribution, Job Briefing
). The employer shall ensure that the employee in charge conducts a job briefing ...
1926.966(g)(2) Electric Power Transmission and Distribution, Job Briefing
The job briefing required by § 1926.952 shall cover information on special system conditions affecting employee safety, including the location ...
OSHA 1926 Construction > V Electric Power Transmission and Distribution > 1926.966 Substations > 1926.966(g) Substation Entry > 1926.966(g)(2) Job Briefing
1926.952(b) Electric Power Transmission and Distribution, Subjects to Be Covered
The briefing shall cover at least the following subjects: Hazards associated with the job, work procedures involved, special precautions, energy ...
OSHA 1926 Construction > V Electric Power Transmission and Distribution > 1926.952 Job Briefing > 1926.952(b) Subjects to Be Covered
1926.952(c)(2) Electric Power Transmission and Distribution, Additional Briefings
Additional job briefings shall be held if significant changes, which might affect the safety of the employees, occur during the course of the work ...
OSHA 1926 Construction > V Electric Power Transmission and Distribution > 1926.952 Job Briefing > 1926.952(c) Number of Briefings > 1926.952(c)(2) Additional Briefings
1926.952(a)(1) Electric Power Transmission and Distribution, Information Provided by the Employer
In assigning an employee or a group of employees to perform a job, the employer shall provide the employee in charge of the job with all available ...
OSHA 1926 Construction > V Electric Power Transmission and Distribution > 1926.952 Job Briefing > 1926.952(a) Before Each Job > 1926.952(a)(1) Information Provided by the Employer