The hydraulic jack shall be supported by a structure of sufficient strength to support the entire static load at rated capacity that is capable of being imposed upon it. The design factor of safety shall be not less than 5, based on ultimate strength for static loads transmitted.

Related Code Sections

3.6.1 Hydraulic Elevators, Jack-Supporting Structure
The hydraulic jack shall be supported by a structure of sufficient strength to support the entire static load at rated capacity that is capable ...
8.4.11.9 General Requirements, Hydraulic Jacks
The attachment of above ground hydraulic jacks to the building structure shall be capable of withstanding the inertia effect of their masses without ...
Section 3.18 Hydraulic Elevators, Hydraulic Jacks
Where multiple hydraulic jacks are used, they shall be hydraulically connected to form a single hydraulic system ...