// CODE SNIPPET
2308.12.6 Irregular Structures
JUMP TO FULL CODE CHAPTER
Conventional light-frame construction shall not be used in irregular portions of structures assigned to Seismic Design Category D or E. Such irregular portions of structures shall be designed to resist the forces specified in Chapter 16 to the extent such irregular features affect the performance of the conventional framing system. A portion of a structure shall be considered to be irregular where one or more of the conditions described in Items 1 through 6 below are present.
- Where exterior braced wall panels are not in one plane vertically from the foundation to the uppermost story in which they are required, the structure shall be considered to be irregular [see Figure 2308.12.6(1)].
Exception: Floors with cantilevers or setbacks not exceeding four times the nominal depth of the floor joists [see Figure 2308.12.6(2)] are permitted to support braced wall panels provided:
- Floor joists are 2 inches by 10 inches (51 mm by 254 mm) or larger and spaced not more than 16 inches (406 mm) o.c.
- The ratio of the back span to the cantilever is at least 2:1.
- Floor joists at ends of braced wall panels are doubled.
- A continuous rim joist is connected to the ends of cantilevered joists. The rim joist is permitted to be spliced using a metal tie not less than 0.058 inch (1.47 mm) (16 galvanized gage) and 11/2 inches (38 mm) wide fastened with six 16d common nails on each side. The metal tie shall have a minimum yield of 33,000 psi (227 MPa).
- Joists at setbacks or the end of cantilevered joists shall not carry gravity loads from more than a single story having uniform wall and roof loads, nor carry the reactions from headers having a span of 8 feet (2438 mm) or more.
- Where a section of floor or roof is not laterally supported by braced wall lines on all edges and connected in accordance with Section 2308.3.2, the structure shall be considered to be irregular [see Figure 2308.12.6(3)].
Exception: Portions of roofs or floors that do not support braced wall panels above are permitted to extend up to 6 feet (1829 mm) beyond a braced wall line [see Figure 2308.12.6(4)] provided that the framing members are connected to the braced wall line below in accordance with Section 2308.3.2.
- Where the end of a required braced wall panel extends more than 1 foot (305 mm) over an opening in the wall below, the structure shall be considered to be irregular. This requirement is applicable to braced wall panels offset in plane and to braced wall panels offset out of plane as permitted by the exception to Item 1 above in this section [see Figure 2308.12.6(5)].
Exception: Braced wall panels are permitted to extend over an opening not more than 8 feet (2438 mm) in width where the header is a 4-inch by 12-inch (102 mm by 305 mm) or larger member.
- Where portions of a floor level are vertically offset such that the framing members on either side of the offset cannot be lapped or tied together in an approved manner, the structure shall be considered to be irregular [see Figure 2308.12.6(6)].
Exception: Framing supported directly by foundations need not be lapped or tied directly together.
- Where braced wall lines are not perpendicular to each other, the structure shall be considered to be irregular [see Figure 2308.12.6(7)].
- Where openings in floor and roof diaphragms having a maximum dimension greater than 50 percent of the distance between lines of bracing or an area greater than 25 percent of the area between orthogonal pairs of braced wall lines are present, the structure shall be considered to be irregular [see Figure 2308.12.6(8)].
FIGURE 2308.12.6(1)
BRACED WALL PANELS OUT OF PLANE
For SI: 1 foot = 304.8 mm.
FIGURE 2308.12.6(2)
BRACED WALL PANELS SUPPORTED BY CANTILEVER OR SET BACK
FIGURE 2308.12.6(3)
FLOOR OR ROOF NOT SUPPORTED ON ALL EDGES
For SI: 1 foot = 304.8 mm.
FIGURE 2308.12.6(4)
ROOF OR FLOOR EXTENSION BEYOND BRACED WALL LINE
For SI: 1 foot = 304.8 mm.
FIGURE 2308.12.6(5)
BRACED WALL PANEL EXTENSION OVER OPENING
FIGURE 2308.12.6(6)
PORTIONS OF FLOOR LEVEL OFFSET VERTICALLY
FIGURE 2308.12.6(7)
BRACED WALL LINES NOT PERPENDICULAR
FIGURE 2308.12.6(8)
OPENING LIMITATIONS FOR FLOOR AND ROOF DIAPHRAGMS
Related Code Sections
2308.12.6 Wood, Irregular Structures
Conventional light-frame construction shall not be used in irregular portions of structures assigned to Seismic Design Category D or E. Such ...
2014 FBC - Building, 5th edition > 23 Wood > 2308 Conventional Light-Frame Construction > 2308.12 Additional Requirements for Conventional Construction in Seismic Design Category D or E > 2308.12.6 Irregular Structures
503.9 Prescriptive Compliance Method, Voluntary Lateral Force-Resisting System Alterations
not create a structural irregularity as defined in ASCE 7 or make an existing structural irregularity more severe ...
2020 FBC - Existing Building, 7th edition > 5 Prescriptive Compliance Method > 503 Alterations > 503.9 Voluntary Lateral Force-Resisting System Alterations
807.6 Alterations — Level 2, Voluntary Lateral Force-Resisting System Alterations
alterations do not create a structural irregularity as defined in ASCE 7 or make an existing structural irregularity more severe ...
2020 FBC - Existing Building, 7th edition > 8 Alterations — Level 2 > 807 Structural > 807.6 Voluntary Lateral Force-Resisting System Alterations
403.5 Prescriptive Compliance Method, Voluntary Seismic Improvements
alterations do not create a structural irregularity as defined in ASCE 7 or make an existing structural irregularity more severe ...
2014 FBC - Existing Building, 5th edition > 4 Prescriptive Compliance Method > 403 Alterations > 403.5 Voluntary Seismic Improvements
403.9 Prescriptive Compliance Method, Voluntary Seismic Improvements
do not create a structural irregularity as defined in ASCE 7 or make an existing structural irregularity more severe ...
2017 FBC - Existing Building, 6th edition > 4 Prescriptive Compliance Method > 403 Alterations > 403.9 Voluntary Seismic Improvements