• Codes
  • Features

    Features Overview

    Go to features
    Reference

    Reference.

    A reliable and up-to-date source of codes.
    Research

    Research.

    Rapidly and efficiently calculate project parameters.
    Collaboration

    Collaboration.

    Get everyone on the same page and streamline code research.
    Workflows
    Architects General Contractor Building Official & Plans Examiner Inspectors Owner Subcontractors Code Consultants
  • Pricing
  • Login
  • Sign Up
Sign Up
Login
  • Code Library
  • Features
  • Pricing
  • About
  • Careers
  • Help
  • Contact
  • Terms
  • Privacy
Sign Up
Upgrade to Premium
Code calculators: Code Calculators automatically generates a detailed list of requirements.
REFERENCE
Amendment Styling
Industry-leading search
Suggested code sections
Code diagrams
RESEARCH
Code calculators
Filter by topic
Code compare
Code sheet exports
COLLABORATION
Team projects
Bookmarks
Comments
START 2 WEEK FREE TRIAL
Have an account? Sign in
// CODE SNIPPET

1910.66(f)(5)(v) Intermittently Stabilized Platforms

OSHA 1910 General Industry > F Powered Platforms, Manlifts, and Vehicle-Mounted Work Platforms > 1910.66 Powered Platforms for Building Maintenance > 1910.66(f) Powered Platform Installations-Equipment > 1910.66(f)(5) Suspended Equipment > 1910.66(f)(5)(v) Intermittently Stabilized Platforms
JUMP TO FULL CODE CHAPTER

1910.66(f)(5)(v)(A)

The platform shall comply with paragraphs (F)(5)(ii) (A) through (M) of this section.

1910.66(f)(5)(v)(B)

Each stabilizer tie shall be equipped with a "quick connect-quick disconnect" device which cannot be accidently disengaged, for attachment to the building anchor, and shall be resistant to adverse environmental conditions.

1910.66(f)(5)(v)(C)

The platform shall be provided with a stopping device that will interrupt the hoist power supply in the event the platform contacts a stabilizer tie during its ascent.

1910.66(f)(5)(v)(D)

Building face rollers shall not be placed at the anchor setting if exterior anchors are used on the building face.

1910.66(f)(5)(v)(E)

Stabilizer ties used on intermittently stabilized platforms shall allow for the specific attachment length needed to effect the predetermined angulation of the suspended wire rope. The specific attachment length shall be maintained at all building anchor locations.

1910.66(f)(5)(v)(F)

The platform shall be in continuous contact with the face of the building during ascent and descent.

1910.66(f)(5)(v)(G)

The attachment and removal of stabilizer ties shall not require the horizontal movement of the platform.

1910.66(f)(5)(v)(H)

The platform-mounted equipment and its suspension wire ropes shall not be physically damaged by the loads from the stabilizer tie or its building anchor. The platform, platform mounted equipment and wire ropes shall be able to withstand a load that is at least twice the ultimate strength of the stabilizer tie.

Note: See figure II in appendix B of this section for a description of a typical intermittent stabilization system.

Related Code Sections


1910.66(f)(5)(v) Powered Platforms, Manlifts, and Vehicle-Mounted Work Platforms, Intermittently Stabilized Platforms
Stabilizer ties used on intermittently stabilized platforms ...
OSHA 1910 General Industry > F Powered Platforms, Manlifts, and Vehicle-Mounted Work Platforms > 1910.66 Powered Platforms for Building Maintenance > 1910.66(f) Powered Platform Installations-Equipment > 1910.66(f)(5) Suspended Equipment > 1910.66(f)(5)(v) Intermittently Stabilized Platforms
1910.66(f)(5)(v)(A) Powered Platforms, Manlifts, and Vehicle-Mounted Work Platforms,
The platform shall comply with paragraphs (F)(5)(ii) (A) through (M) of this section ...
OSHA 1910 General Industry > F Powered Platforms, Manlifts, and Vehicle-Mounted Work Platforms > 1910.66 Powered Platforms for Building Maintenance > 1910.66(f) Powered Platform Installations-Equipment > 1910.66(f)(5) Suspended Equipment > 1910.66(f)(5)(v) Intermittently Stabilized Platforms > 1910.66(f)(5)(v)(A)
1910.66(f)(5)(v)(D) Powered Platforms, Manlifts, and Vehicle-Mounted Work Platforms,
Building face rollers shall not be placed at the anchor setting if exterior anchors are used on the building face ...
OSHA 1910 General Industry > F Powered Platforms, Manlifts, and Vehicle-Mounted Work Platforms > 1910.66 Powered Platforms for Building Maintenance > 1910.66(f) Powered Platform Installations-Equipment > 1910.66(f)(5) Suspended Equipment > 1910.66(f)(5)(v) Intermittently Stabilized Platforms > 1910.66(f)(5)(v)(D)
1910.66(f)(5)(v)(F) Powered Platforms, Manlifts, and Vehicle-Mounted Work Platforms,
The platform shall be in continuous contact with the face of the building during ascent and descent ...
OSHA 1910 General Industry > F Powered Platforms, Manlifts, and Vehicle-Mounted Work Platforms > 1910.66 Powered Platforms for Building Maintenance > 1910.66(f) Powered Platform Installations-Equipment > 1910.66(f)(5) Suspended Equipment > 1910.66(f)(5)(v) Intermittently Stabilized Platforms > 1910.66(f)(5)(v)(F)
1910.66(f)(5) Powered Platforms, Manlifts, and Vehicle-Mounted Work Platforms, Suspended Equipment
Stabilizer ties used on intermittently stabilized platforms shall allow ...
OSHA 1910 General Industry > F Powered Platforms, Manlifts, and Vehicle-Mounted Work Platforms > 1910.66 Powered Platforms for Building Maintenance > 1910.66(f) Powered Platform Installations-Equipment > 1910.66(f)(5) Suspended Equipment
Help Contact Us Privacy Terms
Code Calculators
Code Calculators
Code calculators automatically generate a detailed list of requirements.
Code Compare
Code Compare
Highlight differences between any two building codes.
Search
Search
Don't miss relevant code. Quickly locate sections across your jurisdiction.
Shared projects
Shared projects
Projects provide a dedicated space to collaborate on code research.
Code diagrams
Code diagrams
Unpack the code through illustrations and descriptions.
Code sheet exports
Code sheet exports
Generate a code sheet that integrates with your drawing set.
UpCodes Premium
Leverage the most sophisticated code compliance platform.
TRY FREE FOR TWO WEEKS VISIT PRICING
UpCodes Premium
Leverage the full code compliance platform.
START 2 WEEK FREE TRIAL LEARN MORE