Electric vehicle supply equipment shall be provided with an interlock that de-energizes the electric vehicle connector whenever the electrical connector is uncoupled from the electric vehicle. An interlock shall not be required for portable cord-and-plug-connected electric vehicle supply equipment intended for connection to receptacle outlets rated at 125 volts, single phase, 15 and 20 amperes. An interlock shall not be required for dc supplies less than 60 volts dc.

Related Code Sections

1504.6.1.2.1 Flammable Finishes, Interlocks
The spraying apparatus, drying apparatus and ventilating system for the spray booth or spray room shall be equipped with interlocks arranged ...
2.12.2 Electric Elevators, Interlocks
Each entrance at a landing to an elevator used for passengers or freight and not conforming to 2.12.3.1 shall be equipped with one or more interlocks ...
2.12.2 Electric Elevators, Interlocks
Each entrance at a landing to an elevator used for passengers or freight and not conforming to 2.12.3.1 shall be equipped with one or more interlocks ...
Section 2105 Industrial Ovens, Interlocks
Interlocks shall be provided for Class A ovens so that conveyors or sources of flammable or combustible materials shall shut down if either ...
2404.6.1.2.1 Flammable Finishes, Interlocks
The spraying apparatus, drying apparatus and ventilating system for the spray booth or spray room shall be equipped with interlocks arranged ...