• Codes
  • Features

    Features Overview

    Go to features
    Reference

    Reference.

    A reliable and up-to-date source of codes.
    Research

    Research.

    Rapidly and efficiently calculate project parameters.
    Collaboration

    Collaboration.

    Get everyone on the same page and streamline code research.
    Workflows
    Architects
    Architects
    General Contractors
    General Contractors
    Building Official & Plans Examiners
    Building Official & Plans Examiners
    Inspectors
    Inspectors
    Owners
    Owners
    Subcontractors
    Subcontractors
    Code Consultants
    Code Consultants
  • Pricing
  • Login
  • Sign Up
Sign Up
Login
  • Code Library
  • Features
  • Pricing
  • About
  • Careers
  • Help
  • Contact
  • Terms
  • Privacy
Sign Up
Upgrade to Premium
Code calculators: Code Calculators automatically generates a detailed list of requirements.
REFERENCE
Amendment Styling
Industry-leading search
Code diagrams
RESEARCH
Code calculators
Filter by topic
Code compare
Code sheet exports
COLLABORATION
Team projects
Bookmarks
Comments
START 2 WEEK FREE TRIAL
Have an account? Sign in
// CODE SNIPPET

R303.7 Interior Stairway Illumination

Residential Code 2021 of Colorado > 3 Building Planning > R303 Light, Ventilation and Heating > R303.7 Interior Stairway Illumination
JUMP TO FULL CODE CHAPTER
ILLUSTRATION
Interior stairways shall be provided with an artificial light source to illuminate the landings and treads. The light source shall be capable of illuminating treads and landings to levels of not less than 1 footcandle (11 lux) as measured at the center of treads and landings. There shall be a wall switch at each floor level to control the light source where the stairway has six or more risers.
Exception: A switch is not required where remote, central or automatic control of lighting is provided.

Related Code Sections


R303.7 Building Planning, Interior Stairway Illumination
Interior stairways shall be provided with an artificial light source to illuminate the landings and treads. The light source shall be capable ...
Residential Code 2021 of Colorado > 3 Building Planning > R303 Light, Ventilation and Heating > R303.7 Interior Stairway Illumination
1204.4.1 Interior Environment, Controls
The control for activation of the required stairway lighting shall be in accordance with NFPA 70 ...
Building Code 2021 of Colorado > 12 Interior Environment > 1204 Lighting > 1204.4 Stairway Illumination > 1204.4.1 Controls
1204.4.1 Interior Environment, Controls
The control for activation of the required stairway lighting shall be in accordance with NFPA 70 ...
Building Code of the Department of Personnel & Administration/Office of the State Architect (DPA/OSA) > 12 Interior Environment > 1204 Lighting > 1204.4 Stairway Illumination > 1204.4.1 Controls
1205.4.1 Interior Environment, Controls
The control for activation of the required stairway lighting shall be in accordance with NFPA 70 ...
Building Code of the Department of Personnel & Administration/Office of the State Architect (DPA/OSA) > 12 Interior Environment > 1205 Lighting > 1205.4 Stairway Illumination > 1205.4.1 Controls
1008.3.2 Means of Egress, Buildings
illuminate all of the following areas: Interior exit access stairways and ramps . Interior and exterior exit stairways and ramps . Exit ...
Building Code of the Department of Personnel & Administration/Office of the State Architect (DPA/OSA) > 10 Means of Egress > 1008 Means of Egress Illumination > 1008.3 Emergency Power for Illumination > 1008.3.2 Buildings
Help Contact Us Privacy Terms
Code Calculators
Code Calculators
Code calculators automatically generate a detailed list of requirements.
Code sheet exports
Code sheet exports
Generate a code sheet that integrates with your drawing set.
Shared projects
Shared projects
Projects provide a dedicated space to collaborate on code research.
Code diagrams
Code diagrams
Unpack the code through illustrations and descriptions.
Search
Search
Don't miss relevant code. Quickly locate sections across your jurisdiction.
Code Compare
Code Compare
Highlight differences between any two building codes.
UpCodes Premium
Leverage the most sophisticated code compliance platform.
TRY FREE FOR TWO WEEKS VISIT PRICING
UpCodes Premium
Leverage the full code compliance platform.
START 2 WEEK FREE TRIAL PRICING