• Codes
  • Features

    Features Overview

    Go to features
    Reference

    Reference.

    A reliable and up-to-date source of codes.
    Research

    Research.

    Rapidly and efficiently calculate project parameters.
    Collaboration

    Collaboration.

    Get everyone on the same page and streamline code research.
    Workflows
    Architects General Contractor Building Official & Plans Examiner Inspectors Owner Subcontractors Code Consultants
  • Pricing
  • Login
  • Sign Up
Sign Up
Login
  • Code Library
  • Features
  • Pricing
  • About
  • Careers
  • Help
  • Contact
  • Terms
  • Privacy
Sign Up
Upgrade to Premium
Code calculators: Code Calculators automatically generates a detailed list of requirements.
REFERENCE
Amendment Styling
Industry-leading search
Suggested code sections
Code diagrams
RESEARCH
Code calculators
Filter by topic
Code compare
Code sheet exports
COLLABORATION
Team projects
Bookmarks
Comments
START 2 WEEK FREE TRIAL
Have an account? Sign in
// CODE SNIPPET

1123A.6 Interior Stairway Handrails

Los Angeles Building Code > 11A Housing Accessibility > 1123A Interior Stairways > 1123A.6 Interior Stairway Handrails
JUMP TO FULL CODE CHAPTER

1123A.6.1 Where Required

Stairways shall have handrails on each side. Intermediate handrails shall be located equidistant from the sides of the stairway and comply with Section 1012.9.

Exception: Stairways serving an individual dwelling unit may have one handrail, except that stairways open on one or both sides shall have handrails on the open side or sides.

1123A.6.2 Handrail Configuration

1122A.6.2.6 Cross Section

Handrail gripping surfaces shall comply with this section, or the shape shall provide equivalent gripping surface.

  1. Circular cross section. The handrail gripping surfaces with a circular cross section shall not be less than 11/4 inches (31.75 mm) nor more than 2 inches (50.8 mm) in cross-sectional dimension.
  2. Noncircular cross section. Handrail gripping surfaces with a noncircular cross section shall have a perimeter dimension of 4 inches (102 mm) minimum and 61/4 inches (159 mm) maximum, and a cross-section dimension of 21/4 inches (57 mm) maximum.

1122A.6.2.7 Fittings

Handrails shall not rotate within their fittings.

1123A.6.2.1 Handrail Heights

The top of handrails shall be 34 to 38 inches (864 to 965 mm) above the nosing of the treads.

1123A.6.2.2 Handrail Continuity

Handrails on all stairways shall be continuous within the full length of each stair flight. Inside handrails on switchback or dogleg stairs shall be continuous between stair flights.

1123A.6.2.3 Handrail Extensions

At the top of stair flights, handrails shall extend a minimum of 12 inches (305 mm) horizontally above landings, beginning directly above the first riser nosing. Extensions shall return to a wall, guard, or the walking surface, or shall be continuous to the handrail of an adjacent stair flight.

At the bottom of stair flights, handrails shall extend at the slope of the stair flight for a distance equal to one tread depth beyond the last riser nosing. Such extension shall continue with 12 inches (305 mm) minimum horizontal extension, shall be continuous to the handrail of an adjacent stair flight, or shall return to a wall, guard, or the walking surface. Handrail horizontal extensions shall be in the same direction as the stair flights. (See Figures 11A-6A and 11A-6E.)

Exception: Stairways within an individual dwelling unit.

1123A.6.2.4 Handrail Projections

Handrails projecting from a wall shall have a space of 11/2 inches (38.1 mm) minimum between the wall and the handrail.

Handrails may be located in a recess if the recess is a maximum of 3 inches (76.2 mm) deep and extends at least 18 inches (457 mm) above the top of the rail. Any wall or other surface adjacent to the handrail shall be free of sharp or abrasive elements. (See Figure 11A-6B.)

1123A.6.2.5 Handrail Gripping Surfaces

Handrail gripping surfaces shall be continuous along their length, and shall not be obstructed along their tops or sides. The bottoms of handrail gripping surfaces shall not be obstructed for more than 20 percent of their length. When provided, horizontal projections shall occur 11/2 inches (38 mm) minimum below the bottom of the handrail gripping surface. The distance between horizontal projections and the bottom of the gripping surface shall be permitted to be reduced by 1/8 inch (3.2 mm) for each 1/2 inch (12.7 mm) of additional handrail perimeter dimension that exceeds 4 inches (102 mm).

Handrail gripping surfaces and any surfaces adjacent to them shall be free of sharp or abrasive elements, and shall have rounded edges.

Related Code Sections


1123A.6 Housing Accessibility, Interior Stairway Handrails
Stairways shall have handrails on each side. Intermediate handrails shall be located equidistant from the sides of the stairway and comply ...
Los Angeles Building Code > 11A Housing Accessibility > 1123A Interior Stairways > 1123A.6 Interior Stairway Handrails
1123A.6.2.4 Housing Accessibility, Handrail Projections
Handrails projecting from a wall shall have a space of 1 1 / 2 inches (38.1 mm) minimum between the wall and the handrail. Handrails may be located ...
Los Angeles Building Code > 11A Housing Accessibility > 1123A Interior Stairways > 1123A.6 Interior Stairway Handrails > 1123A.6.2 Handrail Configuration > 1123A.6.2.4 Handrail Projections
1123A.6.2.5 Housing Accessibility, Handrail Gripping Surfaces
Handrail gripping surfaces shall be continuous along their length, and shall not be obstructed along their tops or sides. The bottoms of handrail ...
Los Angeles Building Code > 11A Housing Accessibility > 1123A Interior Stairways > 1123A.6 Interior Stairway Handrails > 1123A.6.2 Handrail Configuration > 1123A.6.2.5 Handrail Gripping Surfaces
1122A.6.2.6 Housing Accessibility, Cross Section
Handrail gripping surfaces shall comply with this section, or the shape shall provide equivalent gripping surface. Circular cross section. The ...
Los Angeles Building Code > 11A Housing Accessibility > 1123A Interior Stairways > 1123A.6 Interior Stairway Handrails > 1123A.6.2 Handrail Configuration > 1122A.6.2.6 Cross Section
1122A.6.2.7 Housing Accessibility, Fittings
Handrails shall not rotate within their fittings ...
Los Angeles Building Code > 11A Housing Accessibility > 1123A Interior Stairways > 1123A.6 Interior Stairway Handrails > 1123A.6.2 Handrail Configuration > 1122A.6.2.7 Fittings
Help Contact Us Privacy Terms
Code sheet exports
Code sheet exports
Generate a code sheet that integrates with your drawing set.
View thousands of relevant UL Certified products and assemblies that help achieve code compliance
View thousands of relevant UL Certified products and assemblies that help achieve code compliance
Access to UL product and system certification information.
Shared projects
Shared projects
Projects provide a dedicated space to collaborate on code research.
Code diagrams
Code diagrams
Unpack the code through illustrations and descriptions.
Code Calculators
Code Calculators
Code calculators automatically generate a detailed list of requirements.
Code Compare
Code Compare
Highlight differences between any two building codes.
Search
Search
Don't miss relevant code. Quickly locate sections across your jurisdiction.
UpCodes Premium
Leverage the most sophisticated code compliance platform.
TRY FREE FOR TWO WEEKS VISIT PRICING
Join the waitlist
We are looking to gauge the level of interest in linking UL product and system certification information alongside related code sections.

Let us know your email and we’ll ping you once it’s ready! Learn more.

Thank you for your interest!

If you’re open to it, we would love to jump on the phone to make sure we’re building this in the best way possible for your workflow. Any insight or advice would be greatly appreciated. We’ve sent you an email with a calendar link to book at time with us.


Cancel
Get Early Access
UpCodes Premium
Leverage the full code compliance platform.
START 2 WEEK FREE TRIAL LEARN MORE