• Codes
  • Features

    Features Overview

    Go to features
    Reference

    Reference.

    A reliable and up-to-date source of codes.
    Research

    Research.

    Rapidly and efficiently calculate project parameters.
    Collaboration

    Collaboration.

    Get everyone on the same page and streamline code research.
    Workflows
    Architects General Contractor Building Official & Plans Examiner Inspectors Owner Subcontractors Code Consultants
  • Pricing
  • Login
  • Sign Up
Sign Up
Login
  • Code Library
  • Features
  • Pricing
  • About
  • Careers
  • Help
  • Contact
  • Terms
  • Privacy
Sign Up
Upgrade to Premium
Code calculators: Code Calculators automatically generates a detailed list of requirements.
REFERENCE
Amendment Styling
Industry-leading search
Suggested code sections
Code diagrams
RESEARCH
Code calculators
Filter by topic
Code compare
Code sheet exports
COLLABORATION
Team projects
Bookmarks
Comments
START 2 WEEK FREE TRIAL
Have an account? Sign in
// CODE SNIPPET

2603.4.1.12 Interior Signs

MA State Building Code, 9th ed, Base Volume > 26 Plastic > 2603 Foam Plastic Insulation > 2603.4 Thermal Barrier > 2603.4.1 Thermal Barrier Not Required > 2603.4.1.12 Interior Signs
JUMP TO FULL CODE CHAPTER
Foam plastic used for interior signs in covered mall buildings in accordance with Section 402.6.4 shall be permitted without a thermal barrier. Foam plastic signs that are not affixed to interior building surfaces shall comply with Chapter 8 of the International Fire Code.

Related Code Sections


2603.4.1.12 Plastic, Interior Signs
Foam plastic used for interior signs in covered mall buildings in accordance with Section 402.16 shall be permitted without a thermal barrier. Foam ...
MA State Building Code, 8th ed, Base Volume > 26 Plastic > 2603 Foam Plastic Insulation > 2603.4 Thermal Barrier > 2603.4.1 Thermal Barrier Not Required > 2603.4.1.12 Interior Signs
2603.4.1.12 Plastic, Interior Signs
Foam plastic used for interior signs in covered mall buildings in accordance with Section 402.6.4 shall be permitted without a thermal barrier ...
MA State Building Code, 9th ed, Base Volume > 26 Plastic > 2603 Foam Plastic Insulation > 2603.4 Thermal Barrier > 2603.4.1 Thermal Barrier Not Required > 2603.4.1.12 Interior Signs
Section 2611 Plastic, Light-Transmitting Plastic Interior Signs
Light-transmitting plastic interior wall signs shall be limited as specified in Sections 2611.2 through 2611.4. Light-transmitting plastic interior ...
MA State Building Code, 8th ed, Base Volume > 26 Plastic > 2611 Light-Transmitting Plastic Interior Signs
Section 2611 Plastic, Light-Transmitting Plastic Interior Signs
Light-transmitting plastic interior wall signs shall be limited as specified in Sections 2611.2 through 2611.4. Light-transmitting plastic interior ...
MA State Building Code, 9th ed, Base Volume > 26 Plastic > 2611 Light-Transmitting Plastic Interior Signs
2611.3 Plastic, Maximum Area
The sign shall not exceed 24 square feet (2.23 m 2 ) ...
MA State Building Code, 8th ed, Base Volume > 26 Plastic > 2611 Light-Transmitting Plastic Interior Signs > 2611.3 Maximum Area
Help Contact Us Privacy Terms
Shared projects
Shared projects
Projects provide a dedicated space to collaborate on code research.
Code Calculators
Code Calculators
Code calculators automatically generate a detailed list of requirements.
Search
Search
Don't miss relevant code. Quickly locate sections across your jurisdiction.
Code diagrams
Code diagrams
Unpack the code through illustrations and descriptions.
Code Compare
Code Compare
Highlight differences between any two building codes.
Code sheet exports
Code sheet exports
Generate a code sheet that integrates with your drawing set.
UpCodes Premium
Leverage the most sophisticated code compliance platform.
TRY FREE FOR TWO WEEKS VISIT PRICING
UpCodes Premium
Leverage the full code compliance platform.
START 2 WEEK FREE TRIAL LEARN MORE