• Codes
  • Features

    Features Overview

    Go to features
    Reference

    Reference.

    A reliable and up-to-date source of codes.
    Research

    Research.

    Rapidly and efficiently calculate project parameters.
    Collaboration

    Collaboration.

    Get everyone on the same page and streamline code research.
    Workflows
    Architects
    Architects
    General Contractors
    General Contractors
    Building Official & Plans Examiners
    Building Official & Plans Examiners
    Inspectors
    Inspectors
    Owners
    Owners
    Subcontractors
    Subcontractors
    Code Consultants
    Code Consultants
  • Pricing
  • Login
  • Sign Up
Sign Up
Login
  • Code Library
  • Features
  • Pricing
  • About
  • Careers
  • Help
  • Contact
  • Terms
  • Privacy
Sign Up
Upgrade to Premium
Code calculators: Code Calculators automatically generates a detailed list of requirements.
REFERENCE
Amendment Styling
Industry-leading search
Code diagrams
RESEARCH
Code calculators
Filter by topic
Code compare
Code sheet exports
COLLABORATION
Team projects
Bookmarks
Comments
START 2 WEEK FREE TRIAL
Have an account? Sign in
// CODE SNIPPET

R602.5 Interior Nonbearing Walls

Residential Code 2021 of Colorado > 6 Wall Construction > R602 Wood Wall Framing > R602.5 Interior Nonbearing Walls
JUMP TO FULL CODE CHAPTER
ILLUSTRATION
Interior nonbearing walls shall be permitted to be constructed with 2-inch by 3- inch (51 mm by 76 mm) studs spaced 24 inches (610 mm) on center or, where not part of a braced wall line, 2-inch by 4- inch (51 mm by 102 mm) flat studs spaced at 16 inches (406 mm) on center. Interior nonbearing walls shall be capped with not less than a single top plate. Interior nonbearing walls shall be fireblocked in accordance with Section R602.8.

Related Code Sections


R602.5 Wall Construction, Interior Nonbearing Walls
Interior nonbearing walls shall be permitted to be constructed with 2-inch by 3- inch (51 mm by 76 mm) studs spaced 24 inches (610 mm) on center ...
Residential Code 2021 of Colorado > 6 Wall Construction > R602 Wood Wall Framing > R602.5 Interior Nonbearing Walls
1705.12.5 Special Inspections and Tests, Architectural Components
Periodic special inspection is required for the erection and fastening of exterior cladding, interior and exterior nonbearing walls and interior ...
Building Code of the Department of Personnel & Administration/Office of the State Architect (DPA/OSA) > 17 Special Inspections and Tests > 1705 Required Special Inspections and Tests > 1705.12 Special Inspections for Seismic Resistance > 1705.12.5 Architectural Components
1705.12.5 Special Inspections and Tests, Architectural Components
Periodic special inspection is required for the erection and fastening of exterior cladding, interior and exterior nonbearing walls and interior ...
Building Code of the Department of Personnel & Administration/Office of the State Architect (DPA/OSA) > 17 Special Inspections and Tests > 1705 Required Special Inspections and Tests > 1705.12 Special Inspections for Seismic Resistance > 1705.12.5 Architectural Components
1705.13.5 Special Inspections and Tests, Architectural Components
Periodic special inspection is required for the erection and fastening of exterior cladding, interior and exterior nonbearing walls and interior ...
Building Code 2021 of Colorado > 17 Special Inspections and Tests > 1705 Required Special Inspections and Tests > 1705.13 Special Inspections for Seismic Resistance > 1705.13.5 Architectural Components
2308.5.2 Wood, Framing Details
of an exterior wall . Exceptions: In interior nonbearing walls and partitions, studs are permitted to be set with the long dimension parallel to the wall ...
Building Code 2021 of Colorado > 23 Wood > 2308 Conventional Light-Frame Construction > 2308.5 Wall Construction > 2308.5.2 Framing Details
Help Contact Us Privacy Terms
Code Compare
Code Compare
Highlight differences between any two building codes.
Shared projects
Shared projects
Projects provide a dedicated space to collaborate on code research.
Code sheet exports
Code sheet exports
Generate a code sheet that integrates with your drawing set.
Code diagrams
Code diagrams
Unpack the code through illustrations and descriptions.
Code Calculators
Code Calculators
Code calculators automatically generate a detailed list of requirements.
Search
Search
Don't miss relevant code. Quickly locate sections across your jurisdiction.
UpCodes Premium
Leverage the most sophisticated code compliance platform.
TRY FREE FOR TWO WEEKS VISIT PRICING
UpCodes Premium
Leverage the full code compliance platform.
START 2 WEEK FREE TRIAL PRICING