902.1 Interceptor
JUMP TO FULL CODE CHAPTER
Vent piping shall be permitted to be omitted on an interceptor where such interceptor acts as a primary settling tank and discharges through a horizontal indirect waste pipe into a secondary interceptor. The second interceptor shall be properly trapped and vented.
Related Code Sections
1014.3.4.1 Traps and Interceptors, Interceptors
Interceptors shall be placed as close as practical to the fixtures they serve ...
Uniform Plumbing Code 2018 of Nevada > 10 Traps and Interceptors > 1014.0 Grease Interceptors > 1014.3 Gravity Grease Interceptors > 1014.3.4 Location > 1014.3.4.1 Interceptors
707.7 Sanitary Drainage, Interceptor
Each cleanout for an interceptor shall be outside of such interceptor ...
902.1 Vents, Interceptor
Vent piping shall be permitted to be omitted on an interceptor where such interceptor acts as a primary settling tank and discharges through ...
H 901.1 Private Sewage Disposal Systems, Interceptor
sewage disposal system, an interceptor for such wastes shall be installed ...
Uniform Plumbing Code 2018 of Nevada > H Private Sewage Disposal Systems > H 901.0 Commercial or Industrial Special Liquid- Waste Disposal > H 901.1 Interceptor