Code calculators: Code Calculators automatically generates a detailed list of requirements.
REFERENCE
Amendment Styling
Industry-leading search
Code diagrams
RESEARCH
Code calculators
Filter by topic
Code compare
Code sheet exports
COLLABORATION
Team projects
Bookmarks
Comments
START 2 WEEK FREE TRIAL
Have an account? Sign in
// CODE SNIPPET

M1412.3 Insulation of Piping

Residential Code 2018 of Kansas > 14 Heating and Cooling Equipment and Appliances > M1412 Absorption Cooling Equipment > M1412.3 Insulation of Piping
JUMP TO FULL CODE CHAPTER
Refrigerant piping, brine piping and fittings within a building shall be insulated to prevent condensation from forming on piping.

Related Code Sections


607.5 Water Supply and Distribution, Insulation of Piping
and piping conveying water heated by a water heater shall be insulated in accordance with Section C404.4 of the International Energy Conservation Code ...
Plumbing Code 2018 of Kansas > 6 Water Supply and Distribution > 607 Hot Water Supply System > 607.5 Insulation of Piping
C404.4 [CE] Commercial Energy Efficiency, Insulation of Piping
Piping from a water heater to the termination of the heated water fixture supply pipe shall be insulated in accordance with Table C403.11.3. On both ...
Energy Conservation Code 2018 of Kansas > 4 [CE] Commercial Energy Efficiency > C404 Service Water Heating (Mandatory) > C404.4 Insulation of Piping
M1412.3 Heating and Cooling Equipment and Appliances, Insulation of Piping
Refrigerant piping, brine piping and fittings within a building shall be insulated to prevent condensation from forming on piping ...
Residential Code 2018 of Kansas > 14 Heating and Cooling Equipment and Appliances > M1412 Absorption Cooling Equipment > M1412.3 Insulation of Piping
M1411.6 Heating and Cooling Equipment and Appliances, Insulation of Refrigerant Piping
Piping and fittings for refrigerant vapor (suction) lines shall be insulated with insulation having a thermal resistivity of not less than R-4 ...
Residential Code 2018 of Kansas > 14 Heating and Cooling Equipment and Appliances > M1411 Heating and Cooling Equipment > M1411.6 Insulation of Refrigerant Piping
Section 1204 Hydronic Piping, Pipe Insulation
Pipe insulation installed in buildings shall conform to the requirements of the International Energy Conservation Code ; shall be tested ...
Mechanical Code 2018 of Kansas > 12 Hydronic Piping > 1204 Pipe Insulation
Help Contact Us Privacy Terms
Code diagrams
Code diagrams
Unpack the code through illustrations and descriptions.
Shared projects
Shared projects
Projects provide a dedicated space to collaborate on code research.
Search
Search
Don't miss relevant code. Quickly locate sections across your jurisdiction.
Code Calculators
Code Calculators
Code calculators automatically generate a detailed list of requirements.
Code sheet exports
Code sheet exports
Generate a code sheet that integrates with your drawing set.
Code Compare
Code Compare
Highlight differences between any two building codes.
UpCodes Premium
Leverage the most sophisticated code compliance platform.
VISIT PRICING
UpCodes Premium
Leverage the full code compliance platform.
START 2 WEEK FREE TRIAL PRICING