Article 316 Insulation of Concealed Pipes Exposed During Alteration or Repair
JUMP TO FULL CODE CHAPTER
Where concealed existing piping is exposed in the course of the alteration or repair of a building, the owner of the building shall provide for the insulation of the exposed piping. The exposed piping shall be insulated to the extent required by the New York city energy conservation code for newly installed pipe of the same specifications and serving the same function as the exposed pipe. The entire exposed length of the piping shall be insulated as well as any further length of concealed pipe that can be directly accessed through openings made in the course of such alteration or repair.
Exceptions:
Exceptions:
- Exposed pipe with one-inch (25-mm) thick continuous coverage of existing insulation in good condition.
- Where the length of concealed pipe which may be directly accessed through openings made in the course of such alteration or repair is less than three feet (914 mm).
- Where there is not sufficient space to insulate pipes to the extent required by the New York city energy conservation code due to conflicts with existing construction, pipes shall be insulated to the extent that space allows.
Related Code Sections
Article 316 Maintenance of Buildings, Insulation of Concealed Pipes Exposed During Alteration or Repair
Where concealed existing piping is exposed in the course of the alteration or repair of a building, the owner of the building shall provide ...
NYC General Admin. Provisions 2014 > 3 Maintenance of Buildings > 316 Insulation of Concealed Pipes Exposed During Alteration or Repair
903.6.2 Fire Protection Systems, Alterations
Cross connections and risers for independent (stand-alone) existing sprinkler systems that are exposed during alterations, including alterations ...
NYC Building Code 2014 > 9 Fire Protection Systems > 903 Automatic Sprinkler Systems > 903.6 Painting of Dedicated Sprinkler Piping and Valve Handles > 903.6.2 Alterations
102.4 Administration, Additions, Alterations or Repairs
Additions, alterations, renovations or repairs to installations shall conform to that required for new installations without requiring the existing ...
NYC Fuel Gas Code 2014 > 1 Administration > 102 Applicability > 102.4 Additions, Alterations or Repairs
§28-105.4.2 Administration, Minor Alterations and Ordinary Repairs
or replacement of plumbing fixtures, piping or faucets from the exposed stop valve to the inlet side of a trap; The alteration or repair of a sign for which ...
NYC General Admin. Provisions 2014 > 1 Administration > 105 Permits > *§28-105.4 Work Exempt From Permit > §28-105.4.2 Minor Alterations and Ordinary Repairs
717.5 Fire and Smoke Protection Features, Combustible Materials in Concealed Spaces in Type I or II Construction
Mechanical Code and the New York City Plumbing Code . Combustible insulation and covering on a pipe and tubing, installed in concealed spaces other than ...
NYC Building Code 2014 > 7 Fire and Smoke Protection Features > 717 Concealed Spaces > 717.5 Combustible Materials in Concealed Spaces in Type I or II Construction