• Codes
  • Features

    Features Overview

    Go to features
    Reference

    Reference.

    A reliable and up-to-date source of codes.
    Research

    Research.

    Rapidly and efficiently calculate project parameters.
    Collaboration

    Collaboration.

    Get everyone on the same page and streamline code research.
    Workflows
    Architects General Contractor Building Official & Plans Examiner Inspectors Owner Subcontractors Code Consultants
  • Pricing
  • Login
  • Sign Up
Sign Up
Login
  • Code Library
  • Features
  • Pricing
  • About
  • Careers
  • Help
  • Contact
  • Terms
  • Privacy
Sign Up
Upgrade to Premium
Code calculators: Code Calculators automatically generates a detailed list of requirements.
REFERENCE
Amendment Styling
Industry-leading search
Suggested code sections
Code diagrams
RESEARCH
Code calculators
Filter by topic
Code compare
Code sheet exports
COLLABORATION
Team projects
Bookmarks
Comments
START 2 WEEK FREE TRIAL
Have an account? Sign in
// CODE SNIPPET

R611.6.3 Insulation Materials

2010 Residential Code of NY > 6 Wall Construction > R611 Insulating Concrete Form Wall Construction > R611.6 Material > R611.6.3 Insulation Materials
JUMP TO FULL CODE CHAPTER
Insulating concrete forms material shall meet the surface burning characteristics of Section R314.3. A thermal barrier shall be provided on the building interior in accordance with Section R314.2 or Section R702.3.4.

Related Code Sections


R611.6.3 Wall Construction, Insulation Materials
Insulating concrete forms material shall meet the surface burning characteristics of Section R314.3. A thermal barrier shall be provided ...
2010 Residential Code of NY > 6 Wall Construction > R611 Insulating Concrete Form Wall Construction > R611.6 Material > R611.6.3 Insulation Materials
M1601.2.1 Duct Systems, Duct Insulation Materials
Duct insulation materials shall conform to the following requirements: Duct coverings and linings, including adhesives where used, shall ...
2010 Residential Code of NY > 16 Duct Systems > M1601 Duct Construction > M1601.2 Factory-Made Ducts > M1601.2.1 Duct Insulation Materials
M1601.3 Duct Systems, Duct Insulation Materials
Duct insulation materials shall conform to the following requirements: Duct coverings and linings, including adhesives where used, shall have ...
Residential Code 2015 of New York State > 16 Duct Systems > M1601 Duct Construction > M1601.3 Duct Insulation Materials
718.2.1.3 Fire and Smoke Protection Features, Loose-Fill Insulation Material
Loose-fill insulation material, insulating foam sealants and caulk materials shall not be used as a fireblock unless specifically tested in the form ...
2020 Building Code of New York State > 7 Fire and Smoke Protection Features > 718 Concealed Spaces > 718.2 Fireblocking > 718.2.1 Fireblocking Materials > 718.2.1.3 Loose-Fill Insulation Material
718.2.1.3 Fire and Smoke Protection Features, Loose-Fill Insulation Material
Loose-fill insulation material, insulating foam sealants and caulk materials shall not be used as a fireblock unless specifically tested in the form ...
Building Code 2015 of New York State > 7 Fire and Smoke Protection Features > 718 Concealed Spaces > 718.2 Fireblocking > 718.2.1 Fireblocking Materials > 718.2.1.3 Loose-Fill Insulation Material
Help Contact Us Privacy Terms
Code sheet exports
Code sheet exports
Generate a code sheet that integrates with your drawing set.
Code Compare
Code Compare
Highlight differences between any two building codes.
Shared projects
Shared projects
Projects provide a dedicated space to collaborate on code research.
View thousands of relevant UL Certified products and assemblies that help achieve code compliance
View thousands of relevant UL Certified products and assemblies that help achieve code compliance
Access to UL product and system certification information.
Search
Search
Don't miss relevant code. Quickly locate sections across your jurisdiction.
Code diagrams
Code diagrams
Unpack the code through illustrations and descriptions.
Code Calculators
Code Calculators
Code calculators automatically generate a detailed list of requirements.
UpCodes Premium
Leverage the most sophisticated code compliance platform.
TRY FREE FOR TWO WEEKS VISIT PRICING
Join the waitlist
We are looking to gauge the level of interest in linking UL product and system certification information alongside related code sections.

Let us know your email and we’ll ping you once it’s ready! Learn more.

Thank you for your interest!

If you’re open to it, we would love to jump on the phone to make sure we’re building this in the best way possible for your workflow. Any insight or advice would be greatly appreciated. We’ve sent you an email with a calendar link to book at time with us.


Cancel
Get Early Access
UpCodes Premium
Leverage the full code compliance platform.
START 2 WEEK FREE TRIAL LEARN MORE