• Codes
  • Features

    Features Overview

    Go to features
    Reference

    Reference.

    A reliable and up-to-date source of codes.
    Research

    Research.

    Rapidly and efficiently calculate project parameters.
    Collaboration

    Collaboration.

    Get everyone on the same page and streamline code research.
    Workflows
    Architects
    Architects
    General Contractors
    General Contractors
    Building Official & Plans Examiners
    Building Official & Plans Examiners
    Inspectors
    Inspectors
    Owners
    Owners
    Subcontractors
    Subcontractors
    Code Consultants
    Code Consultants
  • Pricing
  • Login
  • Sign Up
Sign Up
Login
  • Code Library
  • Features
  • Pricing
  • About
  • Careers
  • Help
  • Contact
  • Terms
  • Privacy
Sign Up
Upgrade to Premium
Code calculators: Code Calculators automatically generates a detailed list of requirements.
REFERENCE
Amendment Styling
Industry-leading search
Code diagrams
RESEARCH
Code calculators
Filter by topic
Code compare
Code sheet exports
COLLABORATION
Team projects
Bookmarks
Comments
START 2 WEEK FREE TRIAL
Have an account? Sign in
// CODE SNIPPET

308.4 Institutional Group I-3

Building Code 2018 of Illinois > 3 Occupancy Classification and Use > 308 Institutional Group I > 308.4 Institutional Group I-3
JUMP TO FULL CODE CHAPTER
Institutional Group I-3 occupancy shall include buildings and structures that are inhabited by more than five persons who are under restraint or security. A Group I-3 facility is occupied by persons who are generally incapable of self-preservation due to security measures not under the occupants' control. This group shall include, but not be limited to, the following:
  • Correctional centers
  • Detention centers
  • Jails
  • Prerelease centers
  • Prisons
  • Reformatories
Buildings of Group I-3 shall be classified as one of the occupancy conditions specified in Sections 308.4.1 through 308.4.5 (see Section 408.1).

308.4.1 Condition 1

This occupancy condition shall include buildings in which free movement is allowed from sleeping areas, and other spaces where access or occupancy is permitted, to the exterior via means of egress without restraint. A Condition 1 facility is permitted to be constructed as Group R.

308.4.2 Condition 2

This occupancy condition shall include buildings in which free movement is allowed from sleeping areas and any other occupied smoke compartment to one or more other smoke compartments. Egress to the exterior is impeded by locked exits.

308.4.3 Condition 3

This occupancy condition shall include buildings in which free movement is allowed within individual smoke compartments, such as within a residential unit comprised of individual sleeping units and group activity spaces, where egress is impeded by remotecontrolled release of means of egress from such a smoke compartment to another smoke compartment.

308.4.4 Condition 4

This occupancy condition shall include buildings in which free movement is restricted from an occupied space. Remote-controlled release is provided to permit movement from sleeping units, activity spaces and other occupied areas within the smoke compartment to other smoke compartments.

308.4.5 Condition 5

This occupancy condition shall include buildings in which free movement is restricted from an occupied space. Staff-controlled manual release is provided to permit movement from sleeping units, activity spaces and other occupied areas within the smoke compartment to other smoke compartments.

Related Code Sections


308.4 Occupancy Classification and Use, Institutional Group I-3
Institutional Group I-3 occupancy shall include buildings and structures that are inhabited by more than five persons who are under restraint ...
Building Code 2021 of Illinois > 3 Occupancy Classification and Use > 308 Institutional Group I > 308.4 Institutional Group I-3
308.4 Occupancy Classification and Use, Institutional Group I-3
Institutional Group I-3 occupancy shall include buildings and structures that are inhabited by more than five persons who are under restraint ...
Building Code 2018 of Illinois > 3 Occupancy Classification and Use > 308 Institutional Group I > 308.4 Institutional Group I-3
308.4.2 Occupancy Classification and Use, Condition 2
This occupancy condition shall include buildings in which free movement is allowed from sleeping areas and any other occupied smoke compartment ...
Building Code 2018 of Illinois > 3 Occupancy Classification and Use > 308 Institutional Group I > 308.4 Institutional Group I-3 > 308.4.2 Condition 2
308.4.4 Occupancy Classification and Use, Condition 4
This occupancy condition shall include buildings in which free movement is restricted from an occupied space. Remote-controlled release is provided ...
Building Code 2021 of Illinois > 3 Occupancy Classification and Use > 308 Institutional Group I > 308.4 Institutional Group I-3 > 308.4.4 Condition 4
308.4.4 Occupancy Classification and Use, Condition 4
This occupancy condition shall include buildings in which free movement is restricted from an occupied space. Remote-controlled release is provided ...
Building Code 2018 of Illinois > 3 Occupancy Classification and Use > 308 Institutional Group I > 308.4 Institutional Group I-3 > 308.4.4 Condition 4
Help Contact Us Privacy Terms
Code Calculators
Code Calculators
Code calculators automatically generate a detailed list of requirements.
Code Compare
Code Compare
Highlight differences between any two building codes.
Shared projects
Shared projects
Projects provide a dedicated space to collaborate on code research.
Search
Search
Don't miss relevant code. Quickly locate sections across your jurisdiction.
Code diagrams
Code diagrams
Unpack the code through illustrations and descriptions.
Code sheet exports
Code sheet exports
Generate a code sheet that integrates with your drawing set.
UpCodes Premium
Leverage the most sophisticated code compliance platform.
VISIT PRICING
UpCodes Premium
Leverage the full code compliance platform.
START 2 WEEK FREE TRIAL PRICING