• Codes
  • Features

    Features Overview

    Go to features
    Reference

    Reference.

    A reliable and up-to-date source of codes.
    Research

    Research.

    Rapidly and efficiently calculate project parameters.
    Collaboration

    Collaboration.

    Get everyone on the same page and streamline code research.
    Workflows
    Architects General Contractor Building Official & Plans Examiner Inspectors Owner Subcontractors Code Consultants
  • Pricing
  • Login
  • Sign Up
Sign Up
Login
  • Code Library
  • Features
  • Pricing
  • About
  • Careers
  • Help
  • Contact
  • Terms
  • Privacy
Sign Up
Upgrade to Premium
Code calculators: Code Calculators automatically generates a detailed list of requirements.
REFERENCE
Amendment Styling
Industry-leading search
Suggested code sections
Code diagrams
RESEARCH
Code calculators
Filter by topic
Code compare
Code sheet exports
COLLABORATION
Team projects
Bookmarks
Comments
START 2 WEEK FREE TRIAL
Have an account? Sign in
// CODE SNIPPET

918.4 Installation on Noncombustible Floors

California Mechanical Code 2019 > 9 Installation of Specific Appliances > 918.0 Food Service Appliance, Floor Mounted > 918.4 Installation on Noncombustible Floors
JUMP TO FULL CODE CHAPTER
Listed floor-installed food service appliances that are designed and marked "For use only in noncombustible locations" shall be installed on floors of noncombustible construction with noncombustible flooring and surface finish and with no combustible material against the underside thereof, or on noncombustible slabs or arches having no combustible material against the underside thereof. Such construction shall in all cases extend not less than 12 inches (305 mm) beyond the appliance on all sides. [NFPA 54:10.12.4.1, 10.12.4.2]

Related Code Sections


918.4 Installation of Specific Appliances, Installation on Noncombustible Floors
Listed floor-installed food service appliances that are designed and marked "For use only in noncombustible locations" shall be installed on floors ...
California Mechanical Code 2019 > 9 Installation of Specific Appliances > 918.0 Food Service Appliance, Floor Mounted > 918.4 Installation on Noncombustible Floors
918.4 Installation of Specific Appliances, Installation on Noncombustible Floors
Listed floor-mounted food service appliances that are designed and marked, "For use only in noncombustible locations," shall be installed on floors ...
California Mechanical Code 2016 > 9 Installation of Specific Appliances > 918.0 Food Service Appliance, Floor Mounted > 918.4 Installation on Noncombustible Floors
931.5.1 Installation of Specific Appliances, Kiln Clearances
a combustible wall surface. Kilns shall be installed on noncombustible flooring consisting of not less than 2 inches (51 mm) of solid masonry or concrete ...
California Mechanical Code 2019 > 9 Installation of Specific Appliances > 931.0 Small Ceramic Kilns > 931.5 Installations Inside Buildings > 931.5.1 Kiln Clearances
932.5.1 Installation of Specific Appliances, Kiln Clearances
a combustible wall surface. Kilns shall be installed on noncombustible flooring consisting of not less than 2 inches (51 mm) of solid masonry or concrete ...
California Mechanical Code 2016 > 9 Installation of Specific Appliances > 932.0 Small Ceramic Kilns > 932.5 Installations Inside Buildings > 932.5.1 Kiln Clearances
Help Contact Us Privacy Terms
Shared projects
Shared projects
Projects provide a dedicated space to collaborate on code research.
Code diagrams
Code diagrams
Unpack the code through illustrations and descriptions.
Search
Search
Don't miss relevant code. Quickly locate sections across your jurisdiction.
Code Calculators
Code Calculators
Code calculators automatically generate a detailed list of requirements.
Code sheet exports
Code sheet exports
Generate a code sheet that integrates with your drawing set.
Code Compare
Code Compare
Highlight differences between any two building codes.
UpCodes Premium
Leverage the most sophisticated code compliance platform.
TRY FREE FOR TWO WEEKS VISIT PRICING
UpCodes Premium
Leverage the full code compliance platform.
START 2 WEEK FREE TRIAL LEARN MORE