706.3 Installation of Fittings
JUMP TO FULL CODE CHAPTER
Fittings shall be installed to guide sewage and waste in the direction of flow. Change in direction shall be made by fittings installed in accordance with Table 706.3. Change in direction by combination fittings, side inlets or increasers shall be installed in accordance with Table 706.3 based on the pattern of flow created by the fitting. Double sanitary tee patterns shall not receive the discharge of back-to-back water closets and fixtures or appliances with pumping action discharge.
Exception: Back-to-back water closet connections to double sanitary tees shall be permitted where the horizontal developed length between the outlet of the water closet and the connection to the double sanitary tee pattern is 18 inches (457 mm) or greater.
FITTINGS FOR CHANGE IN DIRECTION
TYPE OF FITTING PATTERN | CHANGE IN DIRECTION | ||
Horizontal to vertical | Vertical to horizontal | Horizontal to horizontal | |
Sixteenth bend | X | X | X |
Eighth bend | X | X | X |
Sixth bend | X | X | X |
Quarter bend | X | Xa | Xa |
Short sweep | X | Xa,b | Xa |
Long sweep | X | X | X |
Sanitary tee | Xc | — | — |
Wye | X | X | X |
Combination wye and eighth bend | X | X | X |
For SI: 1 inch = 25.4 mm.
- The fittings shall only be permitted for a 2-inch or smaller fixture drain.
- Three inches or larger.
- For a limitation on double sanitary tees, see Section 706.3.
Related Code Sections
706.3 Sanitary Drainage, Installation of Fittings
Fittings shall be installed to guide sewage and waste in the direction of flow. Change in direction shall be made by fittings installed in accordance ...
Plumbing Code 2021 of Alabama > 7 Sanitary Drainage > 706 Connections Between Drainage Piping and Fittings > 706.3 Installation of Fittings
706.3 Sanitary Drainage, Installation of Fittings
Fittings shall be installed to guide sewage and waste in the direction of flow. Change in direction shall be made by fittings installed in accordance ...
Plumbing Code 2009 of Alabama > 7 Sanitary Drainage > 706 Connections Between Drainage Piping and Fittings > 706.3 Installation of Fittings
706.3 Sanitary Drainage, Installation of Fittings
Fittings shall be installed to guide sewage and waste in the direction of flow. Change in direction shall be made by fittings installed in accordance ...
Plumbing Code 2015 of Alabama > 7 Sanitary Drainage > 706 Connections Between Drainage Piping and Fittings > 706.3 Installation of Fittings
16.8.2.1* Installation of Piping, Valves, and Appurtenances,
When nonmetallic fittings are used in systems utilizing internally coated steel piping, the steel pipe shall be listed for compatibility ...
Standard for the Installation of Sprinkler Systems 2019 of Alabama > 16 Installation of Piping, Valves, and Appurtenances > 16.8 Fitting Installation > 16.8.2 Nonmetallic Fittings > 16.8.2.1*
16.8.6.3 Installation of Piping, Valves, and Appurtenances,
The internal diameter of extension fittings shall have the same nominal inlet diameter of the attached sprinkler ...
Standard for the Installation of Sprinkler Systems 2019 of Alabama > 16 Installation of Piping, Valves, and Appurtenances > 16.8 Fitting Installation > 16.8.6 Extension Fitting > 16.8.6.3