• Codes
  • Features

    Features Overview

    Go to features
    Reference

    Reference.

    A reliable and up-to-date source of codes.
    Research

    Research.

    Rapidly and efficiently calculate project parameters.
    Collaboration

    Collaboration.

    Get everyone on the same page and streamline code research.
    Workflows
    Architects General Contractor Building Official & Plans Examiner Inspectors Owner Subcontractors Code Consultants
  • Pricing
  • Login
  • Sign Up
Sign Up
Login
  • Code Library
  • Features
  • Pricing
  • About
  • Careers
  • Help
  • Contact
  • Terms
  • Privacy
Sign Up
Upgrade to Premium
Code calculators: Code Calculators automatically generates a detailed list of requirements.
REFERENCE
Amendment Styling
Industry-leading search
Suggested code sections
Code diagrams
RESEARCH
Code calculators
Filter by topic
Code compare
Code sheet exports
COLLABORATION
Team projects
Bookmarks
Comments
START 2 WEEK FREE TRIAL
Have an account? Sign in
// CODE SNIPPET

A5.205.1.2 Installation of Field-Fabricated Fenestration and Exterior Doors

Los Angeles Green Building Code > A6.1 — Voluntary Standards for Health Facilities [OSHPD 1, 2 & 4] > A5.205 [OSHPD 1 & 4] Building Envelope > A5.205.1 Fenestration Products and Exterior Doors > A5.205.1.2 Installation of Field-Fabricated Fenestration and Exterior Doors
JUMP TO FULL CODE CHAPTER

Field-fabricated fenestration and field-fabricated exterior doors may be installed only if the compliance documentation has demonstrated compliance for the installation using U-factors from Table A5.205.1-A and SHGC values from Table A5.205.1-B. Field-fabricated fenestration and field-fabricated exterior doors shall be caulked between the fenestration products or exterior door and the building and shall be weatherstripped.

Exception: Unframed glass doors and fire doors need not be weatherstripped or caulked.

Related Code Sections


A5.205.1.2 — Voluntary Standards for Health Facilities [OSHPD 1, 2 & 4], Installation of Field-Fabricated Fenestration and Exterior Doors
Field-fabricated fenestration and field-fabricated exterior doors may be installed only if the compliance documentation has demonstrated compliance ...
Los Angeles Green Building Code > A6.1 — Voluntary Standards for Health Facilities [OSHPD 1, 2 & 4] > A5.205 [OSHPD 1 & 4] Building Envelope > A5.205.1 Fenestration Products and Exterior Doors > A5.205.1.2 Installation of Field-Fabricated Fenestration and Exterior Doors
A5.205.1.2 — Voluntary Standards for Health Facilities [OSHPD 1, 2 & 4], Installation of Field-Fabricated Fenestration and Exterior Doors
Field-fabricated fenestration and field-fabricated exterior doors may be installed only if the compliance documentation has demonstrated compliance ...
Los Angeles Green Building Code > A6.1 — Voluntary Standards for Health Facilities [OSHPD 1, 2 & 4] > A5.205 [OSHPD 1 & 4] Building Envelope > A5.205.1 Fenestration Products and Exterior Doors > A5.205.1.2 Installation of Field-Fabricated Fenestration and Exterior Doors
Section A5.505 — Voluntary Standards for Health Facilities [OSHPD 1, 2 & 4], [OSHPD 1, 2 & 4] Indoor Moisture Control
products and exterior door other than field-fabricated.    A5.205.1.2 Installation of field-fabricated fenestration and exterior doors ...
Los Angeles Green Building Code > A6.1 — Voluntary Standards for Health Facilities [OSHPD 1, 2 & 4] > A5.505 [OSHPD 1, 2 & 4] Indoor Moisture Control
Section A5.505 — Voluntary Standards for Health Facilities [OSHPD 1, 2 & 4], [OSHPD 1, 2 & 4] Indoor Moisture Control
products and exterior door other than field-fabricated.    A5.205.1.2 Installation of field-fabricated fenestration and exterior doors ...
Los Angeles Green Building Code > A6.1 — Voluntary Standards for Health Facilities [OSHPD 1, 2 & 4] > A5.505 [OSHPD 1, 2 & 4] Indoor Moisture Control
Section A5.205 — Voluntary Standards for Health Facilities [OSHPD 1, 2 & 4], [OSHPD 1 & 4] Building Envelope
field-fabricated fenestration products and field-fabricated exterior doors, may be installed only if the manufacturer has certified to the California ...
Los Angeles Green Building Code > A6.1 — Voluntary Standards for Health Facilities [OSHPD 1, 2 & 4] > A5.205 [OSHPD 1 & 4] Building Envelope
Help Contact Us Privacy Terms
Code Calculators
Code Calculators
Code calculators automatically generate a detailed list of requirements.
Shared projects
Shared projects
Projects provide a dedicated space to collaborate on code research.
Search
Search
Don't miss relevant code. Quickly locate sections across your jurisdiction.
Code sheet exports
Code sheet exports
Generate a code sheet that integrates with your drawing set.
Code Compare
Code Compare
Highlight differences between any two building codes.
Code diagrams
Code diagrams
Unpack the code through illustrations and descriptions.
UpCodes Premium
Leverage the most sophisticated code compliance platform.
TRY FREE FOR TWO WEEKS VISIT PRICING
UpCodes Premium
Leverage the full code compliance platform.
START 2 WEEK FREE TRIAL LEARN MORE