Signs with tactile characters shall comply with 703.4.
703.4.1 Height Above Finish Floor or Ground
Tactile characters on signs shall be located 48 inches (1220 mm) minimum above the finish floor or ground surface, measured from the baseline of the lowest tactile character and 60 inches (1525 mm) maximum above the finish floor or ground surface, measured from the baseline of the highest tactile character.

EXCEPTION: Tactile characters for elevator car controls shall not be required to comply with 703.4.1.
Figure 703.4.1 Height of Tactile Characters Above Finish Floor or Ground
A tactile sign is shown mounted with the baseline of the lowest characters 48 inches (1220 mm) minimum and the baseline of the highest characters 60 inches (1525 mm) maximum above the finish floor.
703.4.2 Location
Where a tactile sign is provided at a door, the sign shall be located alongside the door at the latch side.  Where a tactile sign is provided at double doors with one active leaf, the sign shall be located on the inactive leaf.  Where a tactile sign is provided at double doors with two active leafs, the sign shall be located to the right of the right hand door.  Where there is no wall space at the latch side of a single door or at the right side of double doors, signs shall be located on the nearest adjacent wall.  Signs containing tactile characters shall be located so that a clear floor space of 18 inches (455 mm) minimum by 18 inches (455 mm) minimum, centered on the tactile characters, is provided beyond the arc of any door swing between the closed position and 45 degree open position.

EXCEPTION: Signs with tactile characters shall be permitted on the push side of doors with closers and without hold-open devices.
Figure 703.4.2 Location of Tactile Signs at Doors
A sign with tactile characters is mounted so that clear floor space 18 by 18 inches (455 by 455 mm) minimum, centered on the tactile characters, is provided beyond the arc of any door swing between the closed position and 45 degree open position.

Related Code Sections

703.4 Communication Elements and Features, Installation Height and Location
Tactile characters on signs shall be located 48 inches (1220 mm) minimum above the finish floor or ground surface, measured from the baseline ...
1005.2.1 Recreation Facilities, Height
  Portions of the railings that are lowered to provide fishing opportunities for persons with disabilities must be located in a variety of locations ...
407.2.1.1 Accessible Routes, Height
Call buttons and keypads shall be located within one of the reach ranges specified in 308, measured to the centerline of the highest operable part ...
611.4 Plumbing Elements and Facilities, Height
Top loading machines shall have the door to the laundry compartment located 36 inches (915 mm) maximum above the finish floor.  Front loading ...
608.3 Plumbing Elements and Facilities, Grab Bars
shall be installed at the same height above the finish floor. EXCEPTIONS: Grab bars shall not be required to be installed in a shower located ...