1707.6 Installation at Truss Ridges
JUMP TO FULL CODE CHAPTER
Where existing conditions prevent installation of lateral braces near the peak of roofs, ridge ties made of minimum 2 × 4 members shall be installed horizontally on faces of trusses to provide anchorage for a required lateral brace. The bottom surfaces of added ridge tie members shall be aligned so that they will support a continuous lateral brace and be installed a maximum of 4 inches (102 mm) below limiting existing conditions for any of the trusses used to support the lateral brace. Ridge ties shall be installed on a minimum of three trusses and on every truss member over which lateral braces pass and be attached to an attic-framing member at least 6 feet (1829 mm) from the exterior sheathing or siding on the gable end wall. Ridge ties shall be placed on alternate sides of trusses. Ridge ties used to support lateral braces shall be fastened to each top chord member of each truss using two (2) 3-inch long fasteners and to any other truss members they cross using three (3) 3-inch long fasteners. Fasteners shall be spaced a minimum 1/2 inch (13 mm) from edges of all members and minimum of 1-inch (25.4 mm) from each other. Lateral braces shall be attached to ridge ties as required by Section 1707.3.1.
Related Code Sections
1707.6 Retrofitting, Installation at Truss Ridges
of the trusses used to support the lateral brace. Ridge ties shall be installed on a minimum of three trusses and on every truss member over which lateral ...
2020 FBC - Existing Building, 7th edition > 17 Retrofitting > 1707 Lateral Braces > 1707.6 Installation at Truss Ridges
1707.6 Retrofitting, Installation at Truss Ridges
of the trusses used to support the lateral brace. Ridge ties shall be installed on a minimum of three trusses and on every truss member over which lateral ...
2017 FBC - Existing Building, 6th edition > 17 Retrofitting > 1707 Lateral Braces > 1707.6 Installation at Truss Ridges
1707.6 Retrofitting, Installation at Truss Ridges
of the trusses used to support the lateral brace. Ridge ties shall be installed on a minimum of three trusses and on every truss member over which lateral ...
2014 FBC - Existing Building, 5th edition > 17 Retrofitting > 1707 Lateral Braces > 1707.6 Installation at Truss Ridges
2303.4 Wood, Trusses
be provided to the building official for approval prior to installation. Truss design drawings shall also be provided with the shipment of trusses delivered ...
2303.4 Wood, Trusses
be provided to the building official for approval prior to installation. Truss design drawings shall also be provided with the shipment of trusses ...