(4) 3308.4 Inspection of Site
JUMP TO FULL CODE CHAPTER
The fire chief or fire prevention officer of the authority having jurisdiction shall inspect the premises where the fireworks exhibition is to take place and determine whether the fireworks exhibition is in compliance with Chapter 3743. of the Revised Code and NFPA 1123 (Chapter 5, site selection) and the applicable portions of NFPA 1126 as listed in rule 1301:7-7-47 of the Administrative Code. The radius of separation distance between all mortars, racks or other points of fireworks discharge and any members of the public shall be measured, regardless of obstruction or other topographical features, as a direct point to point line of sight measurement. All such separation distances shall be measured from the same horizontal plane of elevation between the fireworks discharge point and members of the public. No members of the public shall, regardless of their relative difference in elevation from the horizontal plane of measurement, be permitted within the required radius of separation. For the purposes of this paragraph, the radius of separation extends infinitely above and below the horizontal plane of measurement. The inspection shall be conducted prior to the issuance of the permit for a fireworks exhibition.
Related Code Sections
3308.4 Ohio Administrative Code 1301:7-7-33 Explosives and Fireworks, Inspection of Site
The fire chief or fire prevention officer of the authority having jurisdiction shall inspect the premises where the fireworks exhibition is to take ...
Ohio Fire Code 2011 > Ohio Administrative Code 1301:7-7-33 Explosives and Fireworks > 3308 Fireworks Exhibition > 3308.4 Inspection of Site
3311.6 Ohio Administrative Code 1301:7-7-33 Explosives and Fireworks, Inspection of Site
Prior to issuance, the local fire code official having jurisdiction shall inspect the premises where the flame effects exhibition is to take place ...
Ohio Fire Code 2011 > Ohio Administrative Code 1301:7-7-33 Explosives and Fireworks > 3311 Flame Effects Permit > 3311.6 Inspection of Site
5608.4 Ohio Administrative Code 1301:7-7-56 Explosives and Fireworks, Inspection of Site
The fire chief or fire prevention officer of the authority having jurisdiction shall inspect the premises where the fireworks exhibition is to take ...
2017 Ohio Fire Code > Ohio Administrative Code 1301:7-7-56 Explosives and Fireworks > 5608 Fireworks Exhibition > 5608.4 Inspection of Site
5611.7 Ohio Administrative Code 1301:7-7-56 Explosives and Fireworks, Inspection of Site
Prior to issuance, the local fire code official having jurisdiction shall inspect the premises where the flame effects exhibition is to take place ...
2017 Ohio Fire Code > Ohio Administrative Code 1301:7-7-56 Explosives and Fireworks > 5611 Flame Effects Permit > 5611.7 Inspection of Site
3904.4 Ohio Administrative Code 1301:7-7-39 Plant Processing and Extraction Facilities, Site Inspection
, as approved in paragraph (D)(2)(3904.2) of this rule shall inspect the site of the extraction process once equipment has been installed for compliance ...
2017 Ohio Fire Code > Ohio Administrative Code 1301:7-7-39 Plant Processing and Extraction Facilities > 3904 Systems and Equipment > 3904.4 Site Inspection