• Codes
  • Features

    Features Overview

    Go to features
    Reference

    Reference.

    A reliable and up-to-date source of codes.
    Research

    Research.

    Rapidly and efficiently calculate project parameters.
    Collaboration

    Collaboration.

    Get everyone on the same page and streamline code research.
    Workflows
    Architects
    Architects
    General Contractors
    General Contractors
    Building Official & Plans Examiners
    Building Official & Plans Examiners
    Inspectors
    Inspectors
    Owners
    Owners
    Subcontractors
    Subcontractors
    Code Consultants
    Code Consultants
  • Pricing
  • Login
  • Sign Up
Sign Up
Login
  • Code Library
  • Features
  • Pricing
  • About
  • Careers
  • Help
  • Contact
  • Terms
  • Privacy
Sign Up
Upgrade to Premium
Code calculators: Code Calculators automatically generates a detailed list of requirements.
REFERENCE
Amendment Styling
Industry-leading search
Code diagrams
RESEARCH
Code calculators
Filter by topic
Code compare
Code sheet exports
COLLABORATION
Team projects
Bookmarks
Comments
START 2 WEEK FREE TRIAL
Have an account? Sign in
// CODE SNIPPET

§40-14 Inspection of Gas-Fueled Space and Water Heaters

Title 1 ‒ Department of Buildings > 40 Installation and Maintenance of Gas-Fueled Water and Space Heaters in All Portions of Dwellings Used or Occupied for Living Purposes > §40-14 Inspection of Gas-Fueled Space and Water Heaters
JUMP TO FULL CODE CHAPTER
  1. Where an application has been filed it shall be the responsibility of the inspectors of plumbing to see that gas-fueled space and water heaters are installed in dwellings, apartments and rooms where such heaters are permitted to be installed in lieu of central heat or supply of hot water. They shall see to it that the appliances are of types approved by the Department of Buildings and the American Gas Association, and are installed in compliance with these rules.
  2. An application covering the installation of these appliances in dwellings shall be forwarded directly to the plumbing inspectors when approved as a permit. The installation of such appliances including Type B and other gas vents, but not chimneys, shall be inspected by inspectors of plumbing. If an application does not call for construction of a masonry or metal chimney, it shall be reported as completed, by the plumbing inspector, provided the work was satisfactory with a note on his report "no structural work."
  3. If the application calls for the erection of a masonry or metal chimney, it shall be forwarded by the plumbing inspector to the construction inspector as soon as the plumbing inspector has found the installation of these gas appliances and vent connections satisfactory. The construction inspector shall report such an application completed if the construction of the chimney has been satisfactorily performed.

Related Code Sections


Appendix A Selected Rules of the Department of Buildings [PDF] (page 4)
Inspection of Gas-Fueled Space and Water Heaters §40-15 Issuing Approvals revision: July 1, 2008 400 ...
NYC 1968 Code (Vol II) [PDF] > A Selected Rules of the Department of Buildings
Appendix A Selected Rules of the Department of Buildings [PDF] (page 117)
] when such work is to begin and when it will be ready for operation and inspection. §40-14 Inspection of Gas-Fueled Space and Water Heaters. (a) Where ...
NYC 1968 Code (Vol II) [PDF] > A Selected Rules of the Department of Buildings
Section 502 Water Heaters, Installation
of the New York City Electrical Code. Gas-fired water heaters shall conform to the requirements of the New York City Fuel Gas Code. All water heaters shall ...
NYC Plumbing Code 2014 > 5 Water Heaters > 502 Installation
Section 502 Water Heaters, Installation
heaters shall comply with UL 1453. Gas-fired water heaters shall conform to the requirements of the New York City Fuel Gas Code. All water heaters ...
NYC Plumbing Code 2022 > 5 Water Heaters > 502 Installation
Appendix A Selected Rules of the Department of Buildings [PDF] (page 5)
Materials §40-39 Venting of Gas Appliances §40-40 Gas-Fueled Space Heaters Installed Prior to December 18,1957 §40-41 Gas-Fueled Water Heaters Installed ...
NYC 1968 Code (Vol II) [PDF] > A Selected Rules of the Department of Buildings
Help Contact Us Privacy Terms
Search
Search
Don't miss relevant code. Quickly locate sections across your jurisdiction.
Code diagrams
Code diagrams
Unpack the code through illustrations and descriptions.
Code Compare
Code Compare
Highlight differences between any two building codes.
Code Calculators
Code Calculators
Code calculators automatically generate a detailed list of requirements.
Code sheet exports
Code sheet exports
Generate a code sheet that integrates with your drawing set.
Shared projects
Shared projects
Projects provide a dedicated space to collaborate on code research.
UpCodes Premium
Leverage the most sophisticated code compliance platform.
TRY FREE FOR TWO WEEKS VISIT PRICING
UpCodes Premium
Leverage the full code compliance platform.
START 2 WEEK FREE TRIAL PRICING