(L) Section 3812 Inspection of DOTn Cylinders
JUMP TO FULL CODE CHAPTER
All DOTn cylinders in stationary service on the effective date of this rule, and which are not requalified according to DOTn standards, shall be inspected according to the criteria of sections 5.2.2.2 and 5.2.2.3 of NFPA 58 as listed in rule 1301:7-7-47 of the Administrative Code, no later than September 1, 2008.
Effective Date: November 1, 2011
Prior Effective Dates: 7/1/79; 6/1/85; 6/15/92; 7/1/93; 9/1/95; 3/30/98; 9/1/05; 7/1/07
Related Code Sections
Section 3812 Ohio Administrative Code 1301:7-7-38 Liquefied Petroleum Gases, Inspection of DOTn Cylinders
All DOTn cylinders in stationary service on the effective date of this rule, and which are not requalified according to DOTn standards, shall ...
Ohio Fire Code 2011 > Ohio Administrative Code 1301:7-7-38 Liquefied Petroleum Gases > 3812 Inspection of DOTn Cylinders
2605.4 Ohio Administrative Code 1301:7-7-26 Welding and Other Hot Work, Acetylene Gas
pounds per square inch gauge (psig) (103 kPa) unless dissolved in a suitable solvent in cylinders manufactured in accordance with DOTn 49 CFR Part 178 ...
Ohio Fire Code 2011 > Ohio Administrative Code 1301:7-7-26 Welding and Other Hot Work > 2605 Gas Welding and Cutting > 2605.4 Acetylene Gas
3003.2 Ohio Administrative Code 1301:7-7-30 Compressed Gases, Design and Construction
Compressed gas containers, cylinders and tanks shall be designed, fabricated, tested, marked with the specifications of manufacture and maintained ...
Ohio Fire Code 2011 > Ohio Administrative Code 1301:7-7-30 Compressed Gases > 3003 General Requirements > 3003.2 Design and Construction
3809.7 Ohio Administrative Code 1301:7-7-38 Liquefied Petroleum Gases, Storage in Basement, Pit or Similar Location
unless such location is provided with an approved means of ventilation. Exception: Department of transportation (DOTn) specification cylinders ...
Ohio Fire Code 2011 > Ohio Administrative Code 1301:7-7-38 Liquefied Petroleum Gases > 3809 Storage of Portable LP-gas Containers Awaiting Use or Resale > 3809.7 Storage in Basement, Pit or Similar Location
3507.1.4 Ohio Administrative Code 1301:7-7-35 Flammable Gases and Flammable Cryogenic Fluids, Service Life and Inspection of Containers
Metal hydride storage system cylinders, containers or tanks shall be inspected, tested and requalified for service at not less than five year ...
Ohio Fire Code 2011 > Ohio Administrative Code 1301:7-7-35 Flammable Gases and Flammable Cryogenic Fluids > 3507 Metal Hydride Storage Systems > 3507.1 General Requirements > 3507.1.4 Service Life and Inspection of Containers