G2427.5.5 (503.5.6) Inspection of Chimneys
Go To Full Code Chapter
Before replacing an existing appliance or connecting a vent connector to a chimney, the chimney passageway shall be examined to ascertain that it is clear and free of obstructions and it shall be cleaned if previously used for venting solid or liquid fuel-burning appliances or fireplaces.
G2427.5.5.1 (503.5.6.1) Chimney Lining
Chimneys shall be lined in accordance with NFPA 211.
G2427.5.5.2 (503.5.6.2) Cleanouts
Cleanouts shall be examined and where they do not remain tightly closed when not in use, they shall be repaired or replaced.
G2427.5.5.3 (503.5.6.3) Unsafe Chimneys
Where inspection reveals that an existing chimney is not safe for the intended application, it shall be repaired, rebuilt, lined, relined or replaced with a vent or chimney to conform to NFPA 211 and it shall be suitable for the appliances to be vented.
Upcodes Diagrams
Related Code Sections
G2427.5.5 Fuel Gas, (503.5.6) Inspection of Chimneys
Where inspection reveals that an existing chimney is not safe for the intended application, it shall be repaired, rebuilt, lined ...
G2427.5.5 Fuel Gas, (503.5.6) Inspection of Chimneys
Where inspection reveals that an existing chimney is not safe for the intended application, it shall be repaired, rebuilt, lined ...
G2427.5.5.2 Fuel Gas, (503.5.6.2) Cleanouts
Cleanouts shall be examined and where they do not remain tightly closed when not in use, they shall be repaired or replaced ...
503.5.6 Chimneys and Vents, Inspection of Chimneys
Exception: Where an existing chimney complies with Sections 503.5.6 through 503.5.6.3 and its sizing is in accordance with Section 503.5.5, its continued ...
503.5.6.1 Chimneys and Vents, Chimney Lining
Chimneys shall be lined in accordance with NFPA 211. Exception: Where an existing chimney complies with Sections 503.5.6 through 503.5.6.3 and its ...