• Codes
  • Features

    Features Overview

    Go to features
    Reference

    Reference.

    A reliable and up-to-date source of codes.
    Research

    Research.

    Rapidly and efficiently calculate project parameters.
    Collaboration

    Collaboration.

    Get everyone on the same page and streamline code research.
    Workflows
    Architects General Contractor Building Official & Plans Examiner Inspectors Owner Subcontractors Code Consultants
  • Pricing
  • Login
  • Sign Up
Sign Up
Login
  • Code Library
  • Features
  • Pricing
  • About
  • Careers
  • Help
  • Contact
  • Terms
  • Privacy
Sign Up
Upgrade to Premium
Code calculators: Code Calculators automatically generates a detailed list of requirements.
REFERENCE
Amendment Styling
Industry-leading search
Suggested code sections
Code diagrams
RESEARCH
Code calculators
Filter by topic
Code compare
Code sheet exports
COLLABORATION
Team projects
Bookmarks
Comments
START 2 WEEK FREE TRIAL
Have an account? Sign in
// CODE SNIPPET

G2427.5.5 (503.5.6) Inspection of Chimneys

Residential Code 2015 of New York State > 24 Fuel Gas > G2427 (503) Venting of Appliances > G2427.5 (503.5) Masonry, Metal and Factory-Built Chimneys > G2427.5.5 (503.5.6) Inspection of Chimneys
JUMP TO FULL CODE CHAPTER
Before replacing an existing appliance or connecting a vent connector to a chimney, the chimney passageway shall be examined to ascertain that it is clear and free of obstructions and it shall be cleaned if previously used for venting solid or liquid fuel-burning appliances or fireplaces.

G2427.5.5.1 (503.5.6.1) Chimney Lining

Chimneys shall be lined in accordance with NFPA 211.

Exception: Where an existing chimney complies with Sections G2427.5.5 through G2427.5.5.3 and its sizing is in accordance with Section G2427.5.4, its continued use shall be allowed where the appliance vented by such chimney is replaced by an appliance of similar type, input rating and efficiency.

G2427.5.5.2 (503.5.6.2) Cleanouts

Cleanouts shall be examined to determine if they will remain tightly closed when not in use.

G2427.5.5.3 (503.5.6.3) Unsafe Chimneys

Where inspection reveals that an existing chimney is not safe for the intended application, it shall be repaired, rebuilt, lined, relined or replaced with a vent or chimney to conform to NFPA 211 and it shall be suitable for the appliances to be vented.

Related Code Sections


G2427.5.5 Fuel Gas, (503.5.6) Inspection of Chimneys
Where inspection reveals that an existing chimney is not safe for the intended application, it shall be repaired, rebuilt, lined, relined ...
Residential Code 2015 of New York State > 24 Fuel Gas > G2427 (503) Venting of Appliances > G2427.5 (503.5) Masonry, Metal and Factory-Built Chimneys > G2427.5.5 (503.5.6) Inspection of Chimneys
G2427.5.5 Fuel Gas, (503.5.6) Inspection of Chimneys
Where inspection reveals that an existing chimney is not safe for the intended application, it shall ...
2020 Residential Code of New York State > 24 Fuel Gas > G2427 (503) Venting of Appliances > G2427.5 (503.5) Masonry, Metal and Factory-Built Chimneys > G2427.5.5 (503.5.6) Inspection of Chimneys
G2427.5.5 Fuel Gas, (503.5.6) Inspection of Chimneys
Where inspection reveals that an existing chimney is not safe for the intended application, it shall be repaired, rebuilt, lined, relined ...
2010 Residential Code of NY > 24 Fuel Gas > G2427 (503) Venting of Equipment > G2427.5 (503.5) Masonry, Metal, and Factory-Built Chimneys > G2427.5.5 (503.5.6) Inspection of Chimneys
G2427.5.5.1 Fuel Gas, (503.5.6.1) Chimney Lining
Chimneys shall be lined in accordance with Chapter 10. Exception: Existing chimneys shall be permitted to have their use continued when ...
2010 Residential Code of NY > 24 Fuel Gas > G2427 (503) Venting of Equipment > G2427.5 (503.5) Masonry, Metal, and Factory-Built Chimneys > G2427.5.5 (503.5.6) Inspection of Chimneys > G2427.5.5.1 (503.5.6.1) Chimney Lining
G2427.5.5.2 Fuel Gas, (503.5.6.2) Cleanouts
Cleanouts shall be examined and where they do not remain tightly closed when not in use, they shall be repaired or replaced ...
2020 Residential Code of New York State > 24 Fuel Gas > G2427 (503) Venting of Appliances > G2427.5 (503.5) Masonry, Metal and Factory-Built Chimneys > G2427.5.5 (503.5.6) Inspection of Chimneys > G2427.5.5.2 (503.5.6.2) Cleanouts
Help Contact Us Privacy Terms
Code sheet exports
Code sheet exports
Generate a code sheet that integrates with your drawing set.
Code diagrams
Code diagrams
Unpack the code through illustrations and descriptions.
Code Calculators
Code Calculators
Code calculators automatically generate a detailed list of requirements.
Shared projects
Shared projects
Projects provide a dedicated space to collaborate on code research.
Search
Search
Don't miss relevant code. Quickly locate sections across your jurisdiction.
View thousands of relevant UL Certified products and assemblies that help achieve code compliance
View thousands of relevant UL Certified products and assemblies that help achieve code compliance
Access to UL product and system certification information.
Code Compare
Code Compare
Highlight differences between any two building codes.
UpCodes Premium
Leverage the most sophisticated code compliance platform.
TRY FREE FOR TWO WEEKS VISIT PRICING
Join the waitlist
We are looking to gauge the level of interest in linking UL product and system certification information alongside related code sections.

Let us know your email and we’ll ping you once it’s ready! Learn more.

Thank you for your interest!

If you’re open to it, we would love to jump on the phone to make sure we’re building this in the best way possible for your workflow. Any insight or advice would be greatly appreciated. We’ve sent you an email with a calendar link to book at time with us.


Cancel
Get Early Access
UpCodes Premium
Leverage the full code compliance platform.
START 2 WEEK FREE TRIAL LEARN MORE