• Codes
  • Features

    Features Overview

    Go to features
    Reference

    Reference.

    A reliable and up-to-date source of codes.
    Research

    Research.

    Rapidly and efficiently calculate project parameters.
    Collaboration

    Collaboration.

    Get everyone on the same page and streamline code research.
    Workflows
    Architects General Contractor Building Official & Plans Examiner Inspectors Owner Subcontractors Code Consultants
  • Pricing
  • Login
  • Sign Up
Sign Up
Login
  • Code Library
  • Features
  • Pricing
  • About
  • Careers
  • Help
  • Contact
  • Terms
  • Privacy
Sign Up
Upgrade to Premium
Code calculators: Code Calculators automatically generates a detailed list of requirements.
REFERENCE
Amendment Styling
Industry-leading search
Code diagrams
RESEARCH
Code calculators
Filter by topic
Code compare
Code sheet exports
COLLABORATION
Team projects
Bookmarks
Comments
START 2 WEEK FREE TRIAL
Have an account? Sign in
// CODE SNIPPET

13.6.4.2.1 Inspection Frequency

Fire Code 2015 of Delaware > 13 Fire Protection Systems > 13.6 Portable Fire Extinguishers > 13.6.4 Inspection, Maintenance, and Recharging > 13.6.4.2 Inspection > 13.6.4.2.1 Inspection Frequency
JUMP TO FULL CODE CHAPTER

13.6.4.2.1.1*

Fire extinguishers shall be manually inspected when initially placed in service. [10:7.2.1.1]

13.6.4.2.1.2*

Fire extinguishers and Class D extinguishing agents shall be inspected either manually or by means of an electronic monitoring device/system at intervals not exceeding 31 days. [10:7.2.1.2]

13.6.4.2.1.2.1

Fire extinguishers and Class D extinguishing agents shall be inspected at least once per calendar month. [10:7.2.1.2.1]

13.6.4.2.1.3*

Fire extinguishers and Class D extinguishing agents shall be manually inspected daily or weekly when conditions exist that indicate the need for more frequent inspections. [10:7.2.1.3]

13.6.4.2.1.4

Extinguishers that are electronically monitored for location only, such as those monitored by means of a switch to indicate when the extinguisher is removed from its bracket or cabinet, shall be manually inspected in accordance with 13.6.4.2.2. [10:7.2.1.4]

Related Code Sections


13.6.4.2.1 Fire Protection Systems, Inspection Frequency
Fire extinguishers shall be manually inspected when initially placed in service. [ 10: 7.2.1.1 ...
Fire Code 2015 of Delaware > 13 Fire Protection Systems > 13.6 Portable Fire Extinguishers > 13.6.4 Inspection, Maintenance, and Recharging > 13.6.4.2 Inspection > 13.6.4.2.1 Inspection Frequency
11.3.4.3 Building Services,
The elevator inspections and tests required by 11.3.4.1 shall be performed at frequencies complying with one of the following: Inspection and test ...
Fire Code 2015 of Delaware > 11 Building Services > 11.3 Elevators, Escalators, and Conveyors > 11.3.4 Elevator Testing > 11.3.4.3
9.4.6.3 Building Service and Fire Protection Equipment,
The elevator inspections and tests required by 9.4.6.1 shall be performed at frequencies complying with one of the following: Inspection and test ...
Life Safety Code 2015 of Delaware > 9 Building Service and Fire Protection Equipment > 9.4 Elevators, Escalators, and Conveyors > 9.4.6 Elevator Testing > 9.4.6.3
9.4.6 Building Service and Fire Protection Equipment, Elevator Testing
The elevator inspections and tests required by 9.4.6.1 shall be performed at frequencies complying with one of the following ...
Life Safety Code 2015 of Delaware > 9 Building Service and Fire Protection Equipment > 9.4 Elevators, Escalators, and Conveyors > 9.4.6 Elevator Testing
50.5.4* Commercial Cooking, Inspection for Grease Buildup
The entire exhaust system shall be inspected for grease buildup by a properly trained, qualified, and certified person(s) acceptable to the AHJ ...
Fire Code 2015 of Delaware > 50 Commercial Cooking > 50.5 Procedures for the Use, Inspection, Testing, and Maintenance of Equipment > 50.5.4* Inspection for Grease Buildup
Help Contact Us Privacy Terms
Search
Search
Don't miss relevant code. Quickly locate sections across your jurisdiction.
Shared projects
Shared projects
Projects provide a dedicated space to collaborate on code research.
Code Calculators
Code Calculators
Code calculators automatically generate a detailed list of requirements.
Code diagrams
Code diagrams
Unpack the code through illustrations and descriptions.
Code sheet exports
Code sheet exports
Generate a code sheet that integrates with your drawing set.
Code Compare
Code Compare
Highlight differences between any two building codes.
UpCodes Premium
Leverage the most sophisticated code compliance platform.
TRY FREE FOR TWO WEEKS VISIT PRICING
UpCodes Premium
Leverage the full code compliance platform.
START 2 WEEK FREE TRIAL LEARN MORE