1910.179(j)(1) Inspection Classification
JUMP TO FULL CODE CHAPTER
Prior to initial use all new and altered cranes shall be inspected to insure compliance with the provisions of this section.
Inspection procedure for cranes in regular service is divided into two general classifications based upon the intervals at which inspection should be performed. The intervals in turn are dependent upon the nature of the critical components of the crane and the degree of their exposure to wear, deterioration, or malfunction. The two general classifications are herein designated as "frequent" and "periodic" with respective intervals between inspections as defined below:
Frequent inspection—Daily to monthly intervals.
Periodic inspection—1 to 12-month intervals.
Related Code Sections
1910.179(j)(1) Materials Handling and Storage, Inspection Classification
general classifications based upon the intervals at which inspection should be performed. The intervals in turn are dependent upon the nature ...
OSHA 1910 General Industry > N Materials Handling and Storage > 1910.179 Overhead and Gantry Cranes > 1910.179(j) Inspection— > 1910.179(j)(1) Inspection Classification
1910.180(d) Materials Handling and Storage, Inspection Classification
classifications based upon the intervals at which inspection should be performed. The intervals in turn are dependent upon the nature of the critical ...
OSHA 1910 General Industry > N Materials Handling and Storage > 1910.180 Crawler Locomotive and Truck Cranes > 1910.180(d) Inspection Classification
1910.181(d)(1) Materials Handling and Storage, Inspection Classification
general classifications based upon the intervals at which inspection should be performed. The intervals in turn are dependent upon the nature ...
OSHA 1910 General Industry > N Materials Handling and Storage > 1910.181 Derricks > 1910.181(d) Inspection > 1910.181(d)(1) Inspection Classification
1910.179(j)(1)(i) Materials Handling and Storage, Initial Inspection
Prior to initial use all new and altered cranes shall be inspected to insure compliance with the provisions of this section ...
OSHA 1910 General Industry > N Materials Handling and Storage > 1910.179 Overhead and Gantry Cranes > 1910.179(j) Inspection— > 1910.179(j)(1) Inspection Classification > 1910.179(j)(1)(i) Initial Inspection
1910.180(d)(1) Materials Handling and Storage, Initial Inspection
Prior to initial use all new and altered cranes shall be inspected to insure compliance with provisions of this section ...
OSHA 1910 General Industry > N Materials Handling and Storage > 1910.180 Crawler Locomotive and Truck Cranes > 1910.180(d) Inspection Classification > 1910.180(d)(1) Initial Inspection