• Codes
  • Features

    Features Overview

    Go to features
    Reference

    Reference.

    A reliable and up-to-date source of codes.
    Research

    Research.

    Rapidly and efficiently calculate project parameters.
    Collaboration

    Collaboration.

    Get everyone on the same page and streamline code research.
    Workflows
    Architects
    Architects
    General Contractors
    General Contractors
    Building Official & Plans Examiners
    Building Official & Plans Examiners
    Inspectors
    Inspectors
    Owners
    Owners
    Subcontractors
    Subcontractors
    Code Consultants
    Code Consultants
  • Pricing
  • Login
  • Sign Up
Sign Up
Login
  • Code Library
  • Features
  • Pricing
  • About
  • Careers
  • Help
  • Contact
  • Terms
  • Privacy
Sign Up
Upgrade to Premium
Code calculators: Code Calculators automatically generates a detailed list of requirements.
REFERENCE
Amendment Styling
Industry-leading search
Code diagrams
RESEARCH
Code calculators
Filter by topic
Code compare
Code sheet exports
COLLABORATION
Team projects
Bookmarks
Comments
START 2 WEEK FREE TRIAL
Have an account? Sign in
// CODE SNIPPET

Section 92.0126 Inspection and Inspection Fees

Los Angeles Elevator Code > 1 Administration > 2 Permits, Plan Checks, Fees, Inspections > 92.0126 Inspection and Inspection Fees
JUMP TO FULL CODE CHAPTER
  1. The Department shall cause to be inspected and tested once every year all elevator equipment or related devices governed by this Code.
  2. The Department shall have its representative present to witness all tests made on elevator safety devices, governors and other safety equipment. Every such device shall be stamped with the proper identification and date before the Department may approve such device for use.
  3. The Department shall charge and collect a fee for each periodic inspection made by the Department as follows:

    Private residence elevator.....$58.00

    Dumbwaiter.....$71.00

       (with automatic transfer).....$123.00

    Sidewalk elevator.....$162.00

    Hand elevator.....$58.00

    Escalator and Moving Walk.....$162.00

    Inclined Elevator.....$162.00

    Hydraulic Elevator - Direct Plunger and Cabled.....$162.00

    Cabled elevator:

       10 landings or under.....$214.00

       11 landings but under 20 landings.....$286.00

       21 landings and over.....$357.00

    Fire or Emergency Operation.....$84.00

    Seismic device operation.....$84.00

    Manlift.....$156.00

    Vertical Platform (wheelchair) Lift.....$71.00

    Inclined Platform (wheelchair) Lift.....$71.00

    Stairway Chair lift.....$71.00

    Material Lift with Automatic Transfer Device.....$214.00

    Vertical and Inclined Reciprocating Conveyor.....$214.00

    Rack and Pinion Elevator.....$214.00

    Special Purpose Personnel Elevator.....$214.00

    Automated Guided Vehicles on Guide Ways.....$143.00 per hour

    Conveyance used for Construction.....$143.00 per hour

  4. The periodic inspection fees for any conveyance not listed in Subsection (c), above, that is required to be inspected pursuant to this section, shall be based on similar devices as determined by LAMC Section 92.0202.

Related Code Sections


Section 92.0126 Administration, Inspection and Inspection Fees
and collect a fee for each periodic inspection made by the Department as follows: Private residence elevator.....$58.00 Dumbwaiter ...
Los Angeles Elevator Code > 1 Administration > 2 Permits, Plan Checks, Fees, Inspections > 92.0126 Inspection and Inspection Fees
118.2.2 Scope and Administration, Inspection and RE-Inspection Fee
The additional field inspection and re-inspection fee is for fire/life safety review projects described in Section 118.1.1. The fee shall be based ...
2017 LA Fire Code > 1 Scope and Administration > 118 New Construction Plan Review and Inspection > 118.2 Fees > 118.2.2 Inspection and RE-Inspection Fee
118.2 Scope and Administration, Fees
118.1.1. The fee includes plan review and up to 2 hours of initial field inspection. The fee shall be computed at the Inspector's hourly rate ...
2017 LA Fire Code > 1 Scope and Administration > 118 New Construction Plan Review and Inspection > 118.2 Fees
94.103.4.6.3 Administration, Additional Inspections
employees, the permittee shall pay an additional fee as specified in LAMC Section 98.0412(b) for each additional inspection trip. This fee is in addition ...
Los Angeles Plumbing Code > 1 Administration > 94.103.0 Permits and Inspections > 94.103.4 Fees > 94.103.4.6 Additional Permit and Inspection Fees > 94.103.4.6.3 Additional Inspections
94.103.4.6.4 Administration, Off-Hour Inspections
The Department may, at its discretion, make inspections at other than normal working hours upon application by a permittee as specified in LAMC ...
Los Angeles Plumbing Code > 1 Administration > 94.103.0 Permits and Inspections > 94.103.4 Fees > 94.103.4.6 Additional Permit and Inspection Fees > 94.103.4.6.4 Off-Hour Inspections
Help Contact Us Privacy Terms
Code Compare
Code Compare
Highlight differences between any two building codes.
Code diagrams
Code diagrams
Unpack the code through illustrations and descriptions.
Code Calculators
Code Calculators
Code calculators automatically generate a detailed list of requirements.
Search
Search
Don't miss relevant code. Quickly locate sections across your jurisdiction.
Code sheet exports
Code sheet exports
Generate a code sheet that integrates with your drawing set.
Shared projects
Shared projects
Projects provide a dedicated space to collaborate on code research.
UpCodes Premium
Leverage the most sophisticated code compliance platform.
VISIT PRICING
UpCodes Premium
Leverage the full code compliance platform.
START 2 WEEK FREE TRIAL PRICING