1910.106(g)(3)(ii) Inside Location
JUMP TO FULL CODE CHAPTER
Approved dispensing units may be located inside of buildings. The dispensing area shall be separated from other areas in an approved manner. The dispensing unit and its piping shall be mounted either on a concrete island or protected against collision damage by suitable means and shall be located in a position where it cannot be struck by a vehicle descending a ramp or other slope out of control. The dispensing area shall be provided with an approved mechanical or gravity ventilation system. When dispensing units are located below grade, only approved mechanical ventilation shall be used and the entire dispensing area shall be protected by an approved automatic sprinkler system. Ventilating systems shall be electrically interlocked with gasoline dispensing units so that the dispensing units cannot be operated unless the ventilating fan motors are energized.
Related Code Sections
1910.106(g)(3)(ii) Hazardous Materials, Inside Location
Approved dispensing units may be located inside of buildings. The dispensing area shall be separated from other areas in an approved manner. The ...
OSHA 1910 General Industry > H Hazardous Materials > 1910.106 Flammable Liquids > 1910.106(g) Service Stations > 1910.106(g)(3) Dispensing Systems > 1910.106(g)(3)(ii) Inside Location
1910.272(j)(2)(i)(C) Special Industries,
Floors of enclosed areas containing grain dryers located inside the facility ...
OSHA 1910 General Industry > R Special Industries > 1910.272 Grain Handling Facilities > 1910.272(j) Housekeeping > 1910.272(j)(2) > 1910.272(j)(2)(i) > 1910.272(j)(2)(i)(C)
1910.110(b)(11)(ii)(b) Hazardous Materials,
Located inside the building close to a point at which pipe enters the building provided the capacity of the unit does not exceed 1 quart ...
OSHA 1910 General Industry > H Hazardous Materials > 1910.110 Storage and Handling of Liquefied Petroleum Gases > 1910.110(b) Basic Rules > 1910.110(b)(11) Vaporizer and Housing > 1910.110(b)(11)(ii) > 1910.110(b)(11)(ii)(b)
1910.253(c)(2)(iv) Welding, Cutting, and Brazing,
be located outdoors or in a separate noncombustible building. Such a manifold, if located inside a building having other occupancy, shall be located ...
OSHA 1910 General Industry > Q Welding, Cutting, and Brazing > 1910.253 Oxygen-Fuel Gas Welding and Cutting > 1910.253(c) Manifolding of Cylinders > 1910.253(c)(2) > 1910.253(c)(2)(iv)
1910.111(b)(6)(vi) Hazardous Materials,
Excess flow and back pressure check valves where required by the standards in this section shall be located inside of the container or at a point ...
OSHA 1910 General Industry > H Hazardous Materials > 1910.111 Storage and Handling of Anhydrous Ammonia > 1910.111(b) Basic Rules > 1910.111(b)(6) Container Appurtenances > 1910.111(b)(6)(vi)