// CODE SNIPPET
1926.60(f)(2) Initial Monitoring
JUMP TO FULL CODE CHAPTER
Each employer who has a workplace or work operation covered by this standard shall perform initial monitoring to determine accurately the airborne concentrations of MDA to which employees may be exposed unless:
the employer can demonstrate, on the basis of objective data, that the MDA-containing product or material being handled cannot cause exposures above the standard's action level, even under worst-case release conditions; or
The employer has historical monitoring or other data demonstrating that exposures on a particular job will be below the action level.
Related Code Sections
1926.60(f)(2) Occupational Health and Environmental Controls, Initial Monitoring
Each employer who has a workplace or work operation covered by this standard shall perform initial monitoring to determine accurately the airborne ...
OSHA 1926 Construction > D Occupational Health and Environmental Controls > 1926.60 Methylenedianiline > 1926.60(f) Exposure Monitoring > 1926.60(f)(2) Initial Monitoring
1926.62(d)(4) Occupational Health and Environmental Controls, Positive Initial Determination and Initial Monitoring
the action level the employer shall conduct monitoring which is representative of the exposure for each employee in the workplace who is exposed to lead ...
OSHA 1926 Construction > D Occupational Health and Environmental Controls > 1926.62 Lead > 1926.62(d) Exposure Assessment > 1926.62(d)(4) Positive Initial Determination and Initial Monitoring
1926.1127(n)(2) Toxic and Hazardous Substances, Objective Data for Exemption From Requirement for Initial Monitoring
For purposes of this section, objective data are information demonstrating that a particular product or material containing cadmium or a specific ...
OSHA 1926 Construction > Z Toxic and Hazardous Substances > 1926.1127 Cadmium > 1926.1127(n) Recordkeeping > 1926.1127(n)(2) Objective Data for Exemption From Requirement for Initial Monitoring
1926.1127(l)(3) Toxic and Hazardous Substances, Actions Triggered by Initial Biological Monitoring:
If the results of the biological monitoring tests in the initial examination show the employee's CdU level to be at or below 3 ug/g Cr, B(2)-M level ...
OSHA 1926 Construction > Z Toxic and Hazardous Substances > 1926.1127 Cadmium > 1926.1127(l) Medical Surveillance > 1926.1127(l)(3) Actions Triggered by Initial Biological Monitoring:
1926.1127(n)(2)(i) Toxic and Hazardous Substances,
For purposes of this section, objective data are information demonstrating that a particular product or material containing cadmium or a specific ...
OSHA 1926 Construction > Z Toxic and Hazardous Substances > 1926.1127 Cadmium > 1926.1127(n) Recordkeeping > 1926.1127(n)(2) Objective Data for Exemption From Requirement for Initial Monitoring > 1926.1127(n)(2)(i)