• Codes
  • Features

    Features Overview

    Go to features
    Reference

    Reference.

    A reliable and up-to-date source of codes.
    Research

    Research.

    Rapidly and efficiently calculate project parameters.
    Collaboration

    Collaboration.

    Get everyone on the same page and streamline code research.
    Workflows
    Architects
    Architects
    General Contractors
    General Contractors
    Building Official & Plans Examiners
    Building Official & Plans Examiners
    Inspectors
    Inspectors
    Owners
    Owners
    Subcontractors
    Subcontractors
    Code Consultants
    Code Consultants
  • Pricing
  • Login
  • Sign Up
Sign Up
Login
  • Code Library
  • Features
  • Pricing
  • About
  • Careers
  • Help
  • Contact
  • Terms
  • Privacy
Sign Up
Upgrade to Premium
Code calculators: Code Calculators automatically generates a detailed list of requirements.
REFERENCE
Amendment Styling
Industry-leading search
Code diagrams
RESEARCH
Code calculators
Filter by topic
Code compare
Code sheet exports
COLLABORATION
Team projects
Bookmarks
Comments
START 2 WEEK FREE TRIAL
Have an account? Sign in
// CODE SNIPPET

1908.9.1 Initial Curing

Building Code 2018 of Illinois > 19 Concrete > 1908 Shotcrete > 1908.9 Curing > 1908.9.1 Initial Curing
JUMP TO FULL CODE CHAPTER
Shotcrete shall be kept continuously moist for 24 hours after shotcreting is complete or shall be sealed with an approved curing compound.

Related Code Sections


1908.9.1 Concrete, Initial Curing
Shotcrete shall be kept continuously moist for 24 hours after shotcreting is complete or shall be sealed with an approved curing compound ...
Building Code 2018 of Illinois > 19 Concrete > 1908 Shotcrete > 1908.9 Curing > 1908.9.1 Initial Curing
26.5.3 Construction Documents and Inspection, Curing
' by more than 500 psi. Shotcrete shall be cured in accordance with (1) through (3). For 24 hours from completion of placement, initial ...
Building Code Requirements for Structural Concrete of Illinois > 26 Construction Documents and Inspection > 26.5 Concrete Production and Construction > 26.5.3 Curing
2512.8.2 Gypsum Board, Gypsum Panel Products and Plaster, Curing
Curing of the first coat is permitted to be omitted and the second coat shall be cured as set forth in ASTM C926 and Table 2512.6 ...
Building Code 2021 of Illinois > 25 Gypsum Board, Gypsum Panel Products and Plaster > 2512 Exterior Plaster > 2512.8 Alternate Method of Application > 2512.8.2 Curing
2512.8.2 Gypsum Board, Gypsum Panel Products and Plaster, Curing
Curing of the first coat is permitted to be omitted and the second coat shall be cured as set forth in ASTM C926 and Table 2512.6 ...
Building Code 2018 of Illinois > 25 Gypsum Board, Gypsum Panel Products and Plaster > 2512 Exterior Plaster > 2512.8 Alternate Method of Application > 2512.8.2 Curing
1908.9.3 Concrete, Natural Curing
Natural curing shall not be used in lieu of that specified in this section unless the relative humidity remains at or above 85 percent ...
Building Code 2018 of Illinois > 19 Concrete > 1908 Shotcrete > 1908.9 Curing > 1908.9.3 Natural Curing
Help Contact Us Privacy Terms
Code sheet exports
Code sheet exports
Generate a code sheet that integrates with your drawing set.
Shared projects
Shared projects
Projects provide a dedicated space to collaborate on code research.
Code diagrams
Code diagrams
Unpack the code through illustrations and descriptions.
Code Compare
Code Compare
Highlight differences between any two building codes.
Code Calculators
Code Calculators
Code calculators automatically generate a detailed list of requirements.
Search
Search
Don't miss relevant code. Quickly locate sections across your jurisdiction.
UpCodes Premium
Leverage the most sophisticated code compliance platform.
TRY FREE FOR TWO WEEKS VISIT PRICING
UpCodes Premium
Leverage the full code compliance platform.
START 2 WEEK FREE TRIAL PRICING