// CODE SNIPPET
1910.1050(m)(7) Information Provided to the Examining and Consulting Physicians
Go To Full Code Chapter
1910.1050(m)(7)(i) The Employer Shall Provide the Following Information to the Examining Physician:
1910.1050(m)(7)(i)(A) A Copy of This Regulation and Its Appendices
1910.1050(m)(7)(i)(B)
A description of the affected employee's duties as they relate to the employee's potential exposure to MDA;
1910.1050(m)(7)(i)(C)
The employee's current actual or representative MDA exposure level;
1910.1050(m)(7)(i)(D)
A description of any personal protective equipment used or to be used; and
1910.1050(m)(7)(i)(E)
Information from previous employment-related medical examinations of the affected employee.
1910.1050(m)(7)(ii)
The employer shall provide the foregoing information to a second physician under this section upon request either by the second physician, or by the employee.
Related Code Sections
1910.1050(m)(7) Toxic and Hazardous Substances, Information Provided to the Examining and Consulting Physicians
employer shall provide the foregoing information to a second physician under this section upon request either by the second physician, or by the employee ...
1910.1025(j)(3)(iv) Toxic and Hazardous Substances, Information Provided to Examining and Consulting Physicians
The employer shall provide an initial physician conducting a medical examination or consultation under this section with the following information ...
1910.1050(m)(7)(i)(C) Toxic and Hazardous Substances,
The employee's current actual or representative MDA exposure level ...
OSHA 1910 General Industry > Z Toxic and Hazardous Substances > 1910.1050 Methylenedianiline > 1910.1050(m) Medical Surveillance > 1910.1050(m)(7) Information Provided to the Examining and Consulting Physicians > 1910.1050(m)(7)(i) The Employer Shall Provide the Following Information to the Examining Physician: > 1910.1050(m)(7)(i)(C)
1910.1050(m)(7)(i)(D) Toxic and Hazardous Substances,
A description of any personal protective equipment used or to be used ...
OSHA 1910 General Industry > Z Toxic and Hazardous Substances > 1910.1050 Methylenedianiline > 1910.1050(m) Medical Surveillance > 1910.1050(m)(7) Information Provided to the Examining and Consulting Physicians > 1910.1050(m)(7)(i) The Employer Shall Provide the Following Information to the Examining Physician: > 1910.1050(m)(7)(i)(D)
1910.1025(j)(3)(iv)(B) Toxic and Hazardous Substances,
The employer shall provide the foregoing information to a second or third physician conducting a medical examination or consultation under ...