• Codes
  • Features

    Features Overview

    Go to features
    Reference

    Reference.

    A reliable and up-to-date source of codes.
    Research

    Research.

    Rapidly and efficiently calculate project parameters.
    Collaboration

    Collaboration.

    Get everyone on the same page and streamline code research.
    Workflows
    Architects
    Architects
    General Contractors
    General Contractors
    Building Official & Plans Examiners
    Building Official & Plans Examiners
    Inspectors
    Inspectors
    Owners
    Owners
    Subcontractors
    Subcontractors
    Code Consultants
    Code Consultants
  • Pricing
  • Login
  • Sign Up
Sign Up
Login
  • Code Library
  • Features
  • Pricing
  • About
  • Careers
  • Help
  • Contact
  • Terms
  • Privacy
Sign Up
Upgrade to Premium
Code calculators: Code Calculators automatically generates a detailed list of requirements.
REFERENCE
Amendment Styling
Industry-leading search
Code diagrams
RESEARCH
Code calculators
Filter by topic
Code compare
Code sheet exports
COLLABORATION
Team projects
Bookmarks
Comments
START 2 WEEK FREE TRIAL
Have an account? Sign in
// CODE SNIPPET

91-834 Indoor Public Spaces

NYC Zoning Resolution > IX Special Purpose Districts > 1 - Special Lower Manhattan District (LM) > 91-80 Public Access Areas > 91-83 Retail Uses Within Existing Arcades > 91-834 Indoor Public Spaces
JUMP TO FULL CODE CHAPTER
Indoor public spaces are enclosed, climate-controlled areas on a zoning lot intended for public use and enjoyment. The standards contained within this Section are intended to serve the same purposes outlined for public plazas in Section 37-70. The City Planning Commission may authorize a modification of the provisions of this Section pursuant to Section 91-842 (Authorization to modify design requirements).
(a)        Indoor public spaces shall contain an area of not less than 2,000 square feet and have a minimum width and depth, at any point, of 20 feet. Indoor public spaces shall be located on the ground floor level, shall be directly accessible from all streets or publicly accessible open areas that the space fronts, and shall extend, at a minimum, for the full height of the ground floor level.
(b)        Indoor public spaces shall be fully enclosed, and the transparency requirements of paragraph (c) of Section 91-831 (Ground floor requirements) shall apply to all street walls or building walls facing a publicly accessible open area. The space shall be heated or air-conditioned, and the standards for heating, ventilating and air-conditioning shall be at least equal to those of the lobby for the principal use of the building.
(c)        Public access to the indoor public space shall be provided, at a minimum, between the hours of 6:00 a.m. to 12:00 a.m. The hours of access shall be included on all required entry plaques and information plaques in accordance with the provisions of Section 37-751 (Public space signage systems) and paragraph (i) of this Section.  
(d)        The provisions of Sections 37-718 (Paving), 37-722 (Level of plaza), 37-728 (Standards of accessibility for persons with disabilities), 37-744 (Litter receptacles), 37-745 (Bicycle parking), 37-746 (Drinking fountains), 37-748 (Additional amenities), 37-752 (Prohibition signs), 37-753 (Accessory signs) and 37-77 (Maintenance) shall apply.
(e)        The provisions of Section 37-723 (Circulation paths) for through block public plazas shall apply to through block arcades except as otherwise provided in Section 91-821 (Certification for outdoor cafes within arcades) when a cafe is provided. Trees planted flush-to-grade that measure less than four caliper inches at the time of planting, as permitted by paragraph (h) of this Section, shall not be considered permitted obstructions within circulation paths.
(f)        The provisions of paragraphs (a) and (b) of Section 37-726 (Permitted obstructions) shall apply. A kiosk shall be a permitted obstruction provided that the requirements of paragraph (a) of Section 37-73 (Kiosks and Open Air Cafes) are met. A certification pursuant to Section 37-73 shall not be required to locate a kiosk within an indoor public space. A cafe permitted by certification pursuant to Section 91-821 shall be considered a permitted obstruction within an indoor public space and may not occupy more than 20 percent of the indoor public space area.
(g)        The provisions of Section 37-741 for seating shall apply, except as modified as follows:
(1)        The requirements for seating within 15 feet of a street line shall not apply.
(2)        All of the linear seating capacity may be in moveable seats. Any moveable seats that are provided must remain in the indoor public space during the hours of operation.
(3)        The requirement that seats that face walls must be a minimum of six feet from such wall shall only apply to fixed seating.  
(h)        The requirements of Section 37-742 for planting and trees shall apply, except that the surface area of any vertical planting may be included in the calculation of the total area of planting beds that are provided, and trees shall not be required.  
(i)        Public space signage shall be provided in accordance with the provisions of Section 37-751, except as modified as follows:
(1)        An information plaque shall be provided at each point of pedestrian entry to the indoor public space. Information plaques for through block arcades shall also include lettering stating "PUBLIC ACCESS TO ____ STREET" indicating the opposite street to which the through block connection passes and which lettering shall not be less than three inches in height and located not more than three inches away from the public space symbol. Furthermore, a minimum of one additional information plaque shall be provided within the indoor public space.
(2)        Paragraph (c) shall not apply.
(j)        All indoor public spaces shall be illuminated with a minimum level of illumination of not less than five horizontal foot candles (lumens per foot) throughout the space. The requirements of Section 37-743 for a lighting schedule, a diagram of light level distribution and electrical power shall apply.
(k)        The use requirements of paragraph (b) and the lobby requirements of paragraph (c)(2) of Section 91-831 shall apply to all building walls fronting on an indoor public space that do not face a street or publicly accessible open area. The provisions of paragraph (c) of Section 37-76 for new or existing building walls that are non-transparent shall apply.
(l)        The provisions of Section 37-78 (Compliance) shall be modified as follows:
(1)        paragraph (a) shall not apply; and
(2)        paragraph (b) shall be modified to require that the periodic compliance report shall document compliance with the provisions of Section 37-70 as modified by this Section, and that such report shall also be provided to the local Council Member.
Subsequent design changes to any indoor public space that was subject to the provisions of this Section may only be permitted pursuant to Section 91-837 (Subsequent design changes).

Related Code Sections


§28-111.1.2 Administration, Letters Authorizing Temporary Uses
The commissioner is authorized to issue a letter authorizing the temporary use of outdoor or indoor spaces provided the space shall be occupied ...
NYC General Admin. Provisions 2014 > 1 Administration > 111 Temporary Structures and Uses > §28-111.1 General > §28-111.1.2 Letters Authorizing Temporary Uses
§28-111.1.2 Administration, Letters Authorizing Temporary Uses
The commissioner is authorized to issue a letter authorizing the temporary use of outdoor or indoor spaces provided the space shall be occupied ...
NYC General Admin. Provisions 2022 > 1 Administration > 111 Temporary Structures and Uses > §28-111.1 General > §28-111.1.2 Letters Authorizing Temporary Uses
303.5 General Regulations, Indoor Locations
Maximum indoor temperature in spaces surrounding appliances shall not exceed the greater ...
NYC Fuel Gas Code 2022 > 3 General Regulations > 303 Appliance Location > 303.5 Indoor Locations
304.7.1 General Regulations, Indoor Openings
Where used, openings connecting the interior spaces shall comply with Section 304.5.3 ...
NYC Fuel Gas Code 2008 > 3 General Regulations > 304 Combustion, Ventilation and Dilution Air > 304.7 Combination Indoor and Outdoor Combustion Air > 304.7.1 Indoor Openings
304.7.1 General Regulations, Indoor Openings
Where used, openings connecting the interior spaces shall comply with Section 304.5.3 ...
NYC Fuel Gas Code 2014 > 3 General Regulations > 304 Combustion, Ventilation and Dilution Air > 304.7 Combination Indoor and Outdoor Combustion Air > 304.7.1 Indoor Openings
Help Contact Us Privacy Terms
Search
Search
Don't miss relevant code. Quickly locate sections across your jurisdiction.
Shared projects
Shared projects
Projects provide a dedicated space to collaborate on code research.
Code diagrams
Code diagrams
Unpack the code through illustrations and descriptions.
Code Compare
Code Compare
Highlight differences between any two building codes.
Code sheet exports
Code sheet exports
Generate a code sheet that integrates with your drawing set.
Code Calculators
Code Calculators
Code calculators automatically generate a detailed list of requirements.
UpCodes Premium
Leverage the most sophisticated code compliance platform.
VISIT PRICING
UpCodes Premium
Leverage the full code compliance platform.
START 2 WEEK FREE TRIAL PRICING