• Codes
  • Features

    Features Overview

    Go to features
    Reference

    Reference.

    A reliable and up-to-date source of codes.
    Research

    Research.

    Rapidly and efficiently calculate project parameters.
    Collaboration

    Collaboration.

    Get everyone on the same page and streamline code research.
    Workflows
    Architects General Contractor Building Official & Plans Examiner Inspectors Owner Subcontractors Code Consultants
  • Pricing
  • Login
  • Sign Up
Sign Up
Login
  • Code Library
  • Features
  • Pricing
  • About
  • Careers
  • Help
  • Contact
  • Terms
  • Privacy
Sign Up
Upgrade to Premium
Code calculators: Code Calculators automatically generates a detailed list of requirements.
REFERENCE
Amendment Styling
Industry-leading search
Suggested code sections
Code diagrams
RESEARCH
Code calculators
Filter by topic
Code compare
Code sheet exports
COLLABORATION
Team projects
Bookmarks
Comments
START 2 WEEK FREE TRIAL
Have an account? Sign in
// CODE SNIPPET

[F] 413.4.3 Indoor Installation

Minnesota Fuel Gas Code 2015 > 4 Gas Piping Installations > 413 (IFGC) Compressed Natural Gas Motor Vehicle Fuel-Dispensing Facilities > 413.4 Residential Fueling Appliance Installation > 413.4.3 Indoor Installation
JUMP TO FULL CODE CHAPTER
Where located indoors, residential fueling appliances shall be vented to the outdoors. A gas detector set to operate at one-fifth of the lower limit of flammability of natural gas shall be installed in the room or space containing the appliance. The detector shall be located within 6 inches (152 mm) of the highest point in the room or space. The detector shall stop the operation of the appliance and activate an audible or a visual alarm.

Related Code Sections


1205.6 Energy Systems, Indoor Installations
Stationary fuel cell power systems installed in indoor locations shall comply with Sections 1205.6 through 1205.6.2. For purposes of this section ...
2020 Minnesota State Fire Code > 12 Energy Systems > 1205 Stationary Fuel Cell Power Systems > 1205.6 Indoor Installations
413.4.3 Gas Piping Installations, Indoor Installation
A residential fueling appliance installed indoors or used for indoor fueling shall comply with all of the following: The capacity shall not exceed ...
2020 Minnesota Fuel Gas Code > 4 Gas Piping Installations > 413 (IFGC) Compressed Natural Gas Motor Vehicle Fuel-Dispensing Facilities > 413.4 Residential Fueling Appliance Installation > 413.4.3 Indoor Installation
413.4.3 Gas Piping Installations, Indoor Installation
Where located indoors, residential fueling appliance s shall be vented to the outdoors. A gas detector set to operate at one-fifth of the lower ...
Minnesota Fuel Gas Code 2015 > 4 Gas Piping Installations > 413 (IFGC) Compressed Natural Gas Motor Vehicle Fuel-Dispensing Facilities > 413.4 Residential Fueling Appliance Installation > 413.4.3 Indoor Installation
627.4 Specific Appliances, Clearances for Indoor Installation
Air-conditioning appliances installed in rooms other than alcoves and closets shall be installed with clearances not less than those specified ...
2020 Minnesota Fuel Gas Code > 6 Specific Appliances > 627 (IFGC) Air-Conditioning Appliances > 627.4 Clearances for Indoor Installation
627.4 Specific Appliances, Clearances for Indoor Installation
Air-conditioning appliances installed in rooms other than alcoves and closets shall be installed with clearances not less than those specified ...
Minnesota Fuel Gas Code 2015 > 6 Specific Appliances > 627 (IFGC) Air-Conditioning Appliances > 627.4 Clearances for Indoor Installation
Help Contact Us Privacy Terms
Shared projects
Shared projects
Projects provide a dedicated space to collaborate on code research.
Code Calculators
Code Calculators
Code calculators automatically generate a detailed list of requirements.
Code diagrams
Code diagrams
Unpack the code through illustrations and descriptions.
Search
Search
Don't miss relevant code. Quickly locate sections across your jurisdiction.
Code sheet exports
Code sheet exports
Generate a code sheet that integrates with your drawing set.
Code Compare
Code Compare
Highlight differences between any two building codes.
UpCodes Premium
Leverage the most sophisticated code compliance platform.
TRY FREE FOR TWO WEEKS VISIT PRICING
UpCodes Premium
Leverage the full code compliance platform.
START 2 WEEK FREE TRIAL LEARN MORE