Section 314 Indoor Displays
JUMP TO FULL CODE CHAPTER
Fixtures and displays of goods for sale to the public shall be arranged so as to maintain free, immediate and unobstructed access to exits as required by Chapter 10.
The display of highly combustible goods, including but not limited to fireworks, flammable or combustible liquids, liquefied flammable gases, oxidizing materials, pyroxylin plastics and agricultural goods, in main exit access aisles, corridors, covered and open malls, or within 5 feet (1524 mm) of entrances to exits and exterior exit doors is prohibited where a fire involving such goods would rapidly prevent or obstruct egress.
Liquid-fueled or gaseous-fueled vehicles, boats or other motorcraft shall not be located indoors except as follows:
- Batteries are disconnected except where the fire code official requires that the batteries remain connected to maintain safety features.
- Fuel in fuel tanks does not exceed one-quarter tank or 5 gallons (19 L) (whichever is least).
- Fuel tanks and fill openings are closed and sealed to prevent tampering.
- Vehicles, boats or other motorcraft equipment are not fueled or defueled within the building.
Related Code Sections
Section 314 General Requirements, Indoor Displays
Indoor displays constructed within any occupancy shall comply with Sections 314.2 through 314.4 ...
Section 314 General Requirements, Indoor Displays
Indoor displays constructed within any occupancy shall comply with Sections 314.2 through 314.4 ...
314.3 General Requirements, Highly Combustible Goods
The display of highly combustible goods, including but not limited to fireworks, flammable or combustible liquids, liquefied flammable gases ...
California Fire Code 2019 > 3 General Requirements > 314 Indoor Displays > 314.3 Highly Combustible Goods
314.4 General Requirements, Vehicles
Liquid- or gas-fueled vehicles, boats or other motorcraft shall not be located indoors except as follows: Batteries are disconnected. Fuel in fuel ...
314.4 General Requirements, Vehicles
Liquid-fueled or gaseous-fueled vehicles, boats or other motorcraft shall not be located indoors except as follows: Batteries are disconnected ...