// CODE SNIPPET
408.3 Individual Shower and Tub-Shower Combination Control Valves
JUMP TO FULL CODE CHAPTER
Showers and tub-shower combinations shall
be provided with individual control valves of the pressure balance,
thermostatic, or combination pressure balance/thermostatic
mixing valve type that provide scald and thermal shock protection for the rated flow rate of the installed showerhead.
These valves shall be installed at the point of use and in accordance
with ASSE 1016 or ASME A112.18.1/CSA B125.1.
Gang showers, where supplied with a single temperature-controlled
water supply pipe, shall be controlled by a mixing
valve that is in accordance with ASSE 1069. Handle position
stops shall be provided on such valves and shall be adjusted
per the manufacturer's instructions to deliver a maximum
mixed water setting of 120°F (49°C). Water heater thermostats
shall not be considered a suitable control for meeting
this provision.
Related Code Sections
408.3 Plumbing Fixtures and Fixture Fittings, Individual Shower and Tub-Shower Combination Control Valves
Showers and tub-shower combinations shall
be provided with individual control valves of the pressure balance,
thermostatic, or combination pressure ...
California Plumbing Code 2016 > 4 Plumbing Fixtures and Fixture Fittings > 408.0 Showers > 408.3 Individual Shower and Tub-Shower Combination Control Valves
408.3 Plumbing Fixtures and Fixture Fittings, Individual Shower and Tub-Shower Combination Control Valves
Showers and tub-shower combinations
shall be provided with individual control valves of the
pressure balance, thermostatic, or combination pressure ...
California Plumbing Code 2019 > 4 Plumbing Fixtures and Fixture Fittings > 408.0 Showers > 408.3 Individual Shower and Tub-Shower Combination Control Valves
1224.32.4.4 Interior Environment, Shower or Tub
Each LDR or LDRP room shall have direct access to a private toilet room with shower or tub ...
California Building Code 2016 (Vol 1 & 2) > 12 Interior Environment > 1224 [OSHPD 1] Hospitals > 1224.32 Obstetrical Facilities (Perinatal Unit Space) > 1224.32.4 LDR and LDRP Facilities > 1224.32.4.4 Shower or Tub
417.5 Plumbing Fixtures and Fixture Fittings, Separate Controls for Hot and Cold Water
fitting.
Single-handle mixing valves installed in showers and
tub-shower combinations shall have the flow of hot water ...
California Plumbing Code 2016 > 4 Plumbing Fixtures and Fixture Fittings > 417.0 Faucets and Fixture Fittings > 417.5 Separate Controls for Hot and Cold Water
417.5 Plumbing Fixtures and Fixture Fittings, Separate Controls for Hot and Cold Water
fitting.
Single-handle mixing valves installed in showers and
tub-shower combinations shall have the flow of hot water ...
California Plumbing Code 2019 > 4 Plumbing Fixtures and Fixture Fittings > 417.0 Faucets and Fixture Fittings > 417.5 Separate Controls for Hot and Cold Water