1004.2 Increased Occupant Load

Building Code 2015 of Utah > 10 Means of Egress > 1004 Occupant Load > 1004.2 Increased Occupant Load
JUMP TO FULL CODE CHAPTER
The occupant load permitted in any building, or portion thereof, is permitted to be increased from that number established for the occupancies in Table 1004.1.2, provided that all other requirements of the code are met based on such modified number and the occupant load does not exceed one occupant per 7 square feet (0.65 m2) of occupiable floor space. Where required by the building official, an approved aisle, seating or fixed equipment diagram substantiating any increase in occupant load shall be submitted. Where required by the building official, such diagram shall be posted.
Share URL

Copy and paste the link below into emails, chats or browsers.

Copy

You can also copy or bookmark the link from your browser's address bar.

Related Code Sections


1004.2 Means of Egress, Increased Occupant Load
The occupant load permitted in any building, or portion thereof, is permitted to be increased from that number established for the occupancies ...
Building Code 2015 of Utah > 10 Means of Egress > 1004 Occupant Load > 1004.2 Increased Occupant Load
Section 810 Alterations - Level 2, Plumbing
Where the occupant load of the story is increased by more than 20 percent, plumbing fixtures for the story shall be provided in quantities specified ...
Existing Building Code 2015 of Utah > 8 Alterations - Level 2 > 810 Plumbing
1007.1 Change of Occupancy, Gravity Loads
Buildings or portions thereof subject to a change of occupancy where such change in the nature of occupancy results in higher uniform ...
Existing Building Code 2015 of Utah > 10 Change of Occupancy > 1007 Structural > 1007.1 Gravity Loads
1302.3 Relocated or Moved Buildings, Wind Loads
Detached one- and two-family dwellings and Group U occupancies where wind loads at the new location are not higher than those at the previous ...
Existing Building Code 2015 of Utah > 13 Relocated or Moved Buildings > 1302 Requirements > 1302.3 Wind Loads
1103.2 Additions, Additional Gravity Loads
Exceptions: 1. Structural elements whose stress is not increased by more than 5 percent. 2. Buildings of Group R occupancy with no more ...
Existing Building Code 2015 of Utah > 11 Additions > 1103 Structural > 1103.2 Additional Gravity Loads
About UpCodes

UpCodes provides an intuitive resource to navigate building regulations.

Codes are organized by jurisdiction to help you understand which regulations apply to your project.


Find Your Codes
COMPANY INFO About Contact Careers Terms Privacy
CATEGORY General New York City New York State California Codes Building Codes Online
PREMIUM Features Pricing Sign Up Log In
CODES IBC 2015 IRC 2015 IPC 2015 California Building Code 2016 Popular Sections

FOLLOW US