• Codes
  • Features

    Features Overview

    Go to features
    Reference

    Reference.

    A reliable and up-to-date source of codes.
    Research

    Research.

    Rapidly and efficiently calculate project parameters.
    Collaboration

    Collaboration.

    Get everyone on the same page and streamline code research.
    Workflows
    Architects
    Architects
    General Contractors
    General Contractors
    Building Official & Plans Examiners
    Building Official & Plans Examiners
    Inspectors
    Inspectors
    Owners
    Owners
    Subcontractors
    Subcontractors
    Code Consultants
    Code Consultants
  • Pricing
  • Login
  • Sign Up
Sign Up
Login
  • Code Library
  • Features
  • Pricing
  • About
  • Careers
  • Help
  • Contact
  • Terms
  • Privacy
Sign Up
Upgrade to Premium
Code calculators: Code Calculators automatically generates a detailed list of requirements.
REFERENCE
Amendment Styling
Industry-leading search
Code diagrams
RESEARCH
Code calculators
Filter by topic
Code compare
Code sheet exports
COLLABORATION
Team projects
Bookmarks
Comments
START 2 WEEK FREE TRIAL
Have an account? Sign in
// CODE SNIPPET

63.2.3.1.4 Incompatible Materials

Fire Code 2018 of West Virginia > 63 Compressed Gases and Cryogenic Fluids > 63.2 Building-Related Controls > 63.2.3 Occupancy Protection Levels > 63.2.3.1 Quantity Thresholds for Compressed Gases and Cryogenic Fluids Requiring Special Provisions > 63.2.3.1.4 Incompatible Materials
JUMP TO FULL CODE CHAPTER
When the classification of materials in individual containers requires the area to be placed in more than one protection level, the separation of protection levels shall not be required, provided the area is constructed to meet the requirements of the most restrictive protection level and that the incompatible materials are separated as required by 63.3.1.11.2. [55:6.3.1.4]

Related Code Sections


3.3.180.9* Definitions, Incompatible Material
Materials that, when in contact with each other, have the potential to react in a manner that generates heat, fumes, gases or by-products ...
Fire Code 2018 of West Virginia > 3 Definitions > 3.3 General Definitions > 3.3.180 Material > 3.3.180.9* Incompatible Material
60.2.9 Hazardous Materials, Incompatible Material
See 3.3.175.9 ...
Fire Code 2018 of West Virginia > 60 Hazardous Materials > 60.2 Special Definitions > 60.2.9 Incompatible Material
63.2.3.1.4 Compressed Gases and Cryogenic Fluids, Incompatible Materials
and that the incompatible materials are separated as required by 63.3.1.11.2. [ 55: 6.3.1.4] ...
Fire Code 2018 of West Virginia > 63 Compressed Gases and Cryogenic Fluids > 63.2 Building-Related Controls > 63.2.3 Occupancy Protection Levels > 63.2.3.1 Quantity Thresholds for Compressed Gases and Cryogenic Fluids Requiring Special Provisions > 63.2.3.1.4 Incompatible Materials
63.3.1.11.2* Compressed Gases and Cryogenic Fluids, Incompatible Materials
separation shall not be required between cylinders deemed to be incompatible in gas production facilities where cylinders are connected to manifolds ...
Fire Code 2018 of West Virginia > 63 Compressed Gases and Cryogenic Fluids > 63.3 Compressed Gases > 63.3.1 General > 63.3.1.11 Separation From Hazardous Conditions > 63.3.1.11.2* Incompatible Materials
415.8.2 Special Detailed Requirements Based on Use and Occupancy, Separation of Incompatible Materials
separated from incompatible materials in accordance with the provisions of the NFPA Life Safety Code 2018 edition ...
Building Code 2015 of West Virginia > 4 Special Detailed Requirements Based on Use and Occupancy > 415 Groups H-1, H-2, H-3, H-4 and H-5 > 415.8 Special Provisions for Group H-2 and H-3 Occupancies > 415.8.2 Separation of Incompatible Materials
Help Contact Us Privacy Terms
Code Compare
Code Compare
Highlight differences between any two building codes.
Shared projects
Shared projects
Projects provide a dedicated space to collaborate on code research.
Code Calculators
Code Calculators
Code calculators automatically generate a detailed list of requirements.
Code diagrams
Code diagrams
Unpack the code through illustrations and descriptions.
Code sheet exports
Code sheet exports
Generate a code sheet that integrates with your drawing set.
Search
Search
Don't miss relevant code. Quickly locate sections across your jurisdiction.
UpCodes Premium
Leverage the most sophisticated code compliance platform.
VISIT PRICING
UpCodes Premium
Leverage the full code compliance platform.
START 2 WEEK FREE TRIAL PRICING