(C) In Unfinished Basements and Crawl Spaces
JUMP TO FULL CODE CHAPTER
Where cable is run at angles with joists in unfinished basements and crawl spaces, it shall be permissible to secure cables not smaller than two 6 AWG or three 8 AWG conductors directly to the lower edges of the joists. Smaller cables shall be run either through bored holes in joists or on running boards. Nonmetallic-sheathed cable installed on the wall of an unfinished basement shall be permitted to be installed in a listed conduit or tubing or shall be protected in accordance with 300.4. Conduit or tubing shall be provided with a suitable insulating bushing or adapter at the point the cable enters the raceway. The sheath of the nonmetallic-sheathed cable shall extend through the conduit or tubing and into the outlet or device box not less than 6 mm (1/4 in.). The cable shall be secured within 300 mm (12 in.) of the point where the cable enters the conduit or tubing. Metal conduit, tubing, and metal outlet boxes shall be connected to an equipment grounding conductor complying with the provisions of 250.86 and 250.148.
Related Code Sections
(C) Wiring Methods and Materials, In Unfinished Basements and Crawl Spaces
Where cable is run at angles with joists in unfinished basements and crawl spaces, it shall be permissible to secure cables not smaller than two 6 ...
National Electrical Code 2020 of Illinois > 3 Wiring Methods and Materials > 334 Nonmetallic-Sheathed Cable: Types NM and NMC > 334.15 Exposed Work > (C) In Unfinished Basements and Crawl Spaces
(C) Wiring Methods and Materials, In Unfinished Basements and Crawl Spaces
Where cable is run at angles with joists in unfinished basements and crawl spaces, it shall be permissible to secure cables not smaller than two 6 ...
National Electrical Code 2017 of Illinois > 3 Wiring Methods and Materials > 334 Nonmetallic-Sheathed Cable: Types NM, NMC, and NMS > 334.15 Exposed Work > (C) In Unfinished Basements and Crawl Spaces
29.8.1.1* Single- And Multiple-Station Alarms and Household Signaling Systems,
level of a residential board and care occupancy (small facility), including basements and excluding crawl spaces and unfinished attics * In the living ...
National Fire Alarm and Signaling Code 2019 of Illinois > 29 Single- And Multiple-Station Alarms and Household Signaling Systems > 29.8 Detection and Notification > 29.8.1* Required Smoke Detection > 29.8.1.1*
(3) Wiring and Protection, Basements
In each separate unfinished portion of a basement ...
National Electrical Code 2017 of Illinois > 2 Wiring and Protection > 210 Branch Circuits > 210.52 Dwelling Unit Receptacle Outlets > (G) Basements, Garages, and Accessory Buildings > (3) Basements
(3) Wiring and Protection, Basements
In each separate unfinished portion of a basement ...
National Electrical Code 2020 of Illinois > 2 Wiring and Protection > 210 Branch Circuits > 210.52 Dwelling Unit Receptacle Outlets > (G) Basements, Garages, and Accessory Buildings > (3) Basements