• Codes
  • Features

    Features Overview

    Go to features
    Reference

    Reference.

    A reliable and up-to-date source of codes.
    Research

    Research.

    Rapidly and efficiently calculate project parameters.
    Collaboration

    Collaboration.

    Get everyone on the same page and streamline code research.
    Workflows
    Architects General Contractor Building Official & Plans Examiner Inspectors Owner Subcontractors Code Consultants
  • Pricing
  • Login
  • Sign Up
Sign Up
Login
  • Code Library
  • Features
  • Pricing
  • About
  • Careers
  • Help
  • Contact
  • Terms
  • Privacy
Sign Up
Upgrade to Premium
Code calculators: Code Calculators automatically generates a detailed list of requirements.
REFERENCE
Amendment Styling
Industry-leading search
Suggested code sections
Code diagrams
RESEARCH
Code calculators
Filter by topic
Code compare
Code sheet exports
COLLABORATION
Team projects
Bookmarks
Comments
START 2 WEEK FREE TRIAL
Have an account? Sign in
// CODE SNIPPET

1807.5 In Situ Walls

NYC Building Code 2014 > 18 Soils and Foundations > 1807 Dampproofing and Waterproofing > 1807.5 In Situ Walls
JUMP TO FULL CODE CHAPTER
In situ walls (such as slurry walls, tangent pile walls, and secant pile walls) with joints sealed by grouting or other methods acceptable to the engineer shall not require waterproofing or dampproofing unless required by the engineer.

Related Code Sections


1807.5 Soils and Foundations, In-Situ Walls
Applied waterproofing or damp-proofing need not be applied to slurry walls, or walls constructed below the water table. In-situ walls shall ...
NYC Building Code 2008 > 18 Soils and Foundations > 1807 Dampproofing and Waterproofing > 1807.5 In-Situ Walls
1807.5 Soils and Foundations, In Situ Walls
In situ walls (such as slurry walls, tangent pile walls, and secant pile walls) with joints sealed by grouting or other methods acceptable ...
NYC Building Code 2014 > 18 Soils and Foundations > 1807 Dampproofing and Waterproofing > 1807.5 In Situ Walls
1604.6 Structural Design, In-Situ Load Tests
The commissioner is authorized to require an engineering analysis or a load test, or both, of any construction whenever ...
NYC Building Code 2008 > 16 Structural Design > 1604 General Design Requirements > 1604.6 In-Situ Load Tests
1604.6 Structural Design, In-Situ Load Tests
The commissioner is authorized to require an engineering analysis or a load test, or both, of any construction whenever there is reason to question ...
NYC Building Code 2014 > 16 Structural Design > 1604 General Design Requirements > 1604.6 In-Situ Load Tests
Section 1713 Structural Tests and Special Inspections, In-Situ Load Tests
In-situ load tests shall be conducted in accordance ...
NYC Building Code 2008 > 17 Structural Tests and Special Inspections > 1713 In-Situ Load Tests
Help Contact Us Privacy Terms
Shared projects
Shared projects
Projects provide a dedicated space to collaborate on code research.
Search
Search
Don't miss relevant code. Quickly locate sections across your jurisdiction.
Code sheet exports
Code sheet exports
Generate a code sheet that integrates with your drawing set.
Code Compare
Code Compare
Highlight differences between any two building codes.
Code diagrams
Code diagrams
Unpack the code through illustrations and descriptions.
Code Calculators
Code Calculators
Code calculators automatically generate a detailed list of requirements.
UpCodes Premium
Leverage the most sophisticated code compliance platform.
TRY FREE FOR TWO WEEKS VISIT PRICING
UpCodes Premium
Leverage the full code compliance platform.
START 2 WEEK FREE TRIAL LEARN MORE