P-902.3.1 In Separate Trench
JUMP TO FULL CODE CHAPTER
For house drains installed beyond the building wall in a trench separate from water
service or water distribution pipe, the drain pipe shall be of cast iron hard temper copper tube of a weight not less than type "L", vitrified clay pipe, concrete, or plastic. If the drain consists of plastic materials, the underground
water service or water distribution pipe and the house drain shall be not less than 10 feet apart horizontally and shall
be separated by undisturbed or compacted earth, or shall be in accordance with Section P-805 when approved by
the Department.
Related Code Sections
P-902.3.1 Soil and Waste Piping, In Separate Trench
For house drains installed beyond the building wall in a trench separate from water
service or water distribution pipe, the drain pipe shall ...
Philadelphia Plumbing Code > 9 Soil and Waste Piping > P-902 Materials > P-902.3 House Drains > P-902.3.1 In Separate Trench
404.13 Gas Piping Installations, Trenches
The trench shall be graded so that the pipe has a firm, substantially continuous bearing on the bottom of the trench ...
Philadelphia Fuel Gas Code > 4 Gas Piping Installations > 404 (IFGC) Piping System Installation > 404.13 Trenches
306.2 General Regulations, Trenching and Bedding
Where trenches are excavated such that the bottom of the trench forms the bed for the pipe, solid and continuous load-bearing support shall ...
Plumbing Code 2018 of Philadelphia > 3 General Regulations > 306 Trenching, Excavation and Backfill > 306.2 Trenching and Bedding
Section 413 Fixtures, Faucets and Fixture Fittings, Floor and Trench Drains
Floor drains shall conform to ASME A112.3.1, ASME A112.6.3 or CSA B79. Trench drains shall comply with ASME A112.6.3 ...
Plumbing Code 2018 of Philadelphia > 4 Fixtures, Faucets and Fixture Fittings > 413 Floor and Trench Drains
G2415.13 Fuel Gas, (404.13) Trenches
The trench shall be graded so that the pipe has a firm, substantially continuous bearing on the bottom of the trench ...
Philadelphia Residential Code > 24 Fuel Gas > G2415 (404) Piping System Installation > G2415.13 (404.13) Trenches