• Codes
  • Features

    Features Overview

    Go to features
    Reference

    Reference.

    A reliable and up-to-date source of codes.
    Research

    Research.

    Rapidly and efficiently calculate project parameters.
    Collaboration

    Collaboration.

    Get everyone on the same page and streamline code research.
    Workflows
    Architects General Contractor Building Official & Plans Examiner Inspectors Owner Subcontractors Code Consultants
  • Pricing
  • Login
  • Sign Up
Sign Up
Login
  • Code Library
  • Features
  • Pricing
  • About
  • Careers
  • Help
  • Contact
  • Terms
  • Privacy
Sign Up
Upgrade to Premium
Code calculators: Code Calculators automatically generates a detailed list of requirements.
REFERENCE
Amendment Styling
Industry-leading search
Code diagrams
RESEARCH
Code calculators
Filter by topic
Code compare
Code sheet exports
COLLABORATION
Team projects
Bookmarks
Comments
START 2 WEEK FREE TRIAL
Have an account? Sign in
// CODE SNIPPET

73-202 In M1-5A or M1-5B Districts

NYC Zoning Resolution > VII Administration > 3 - Special Permits by the Board of Standards and Appeals > 73-20 Theaters > 73-202 In M1-5A or M1-5B Districts
JUMP TO FULL CODE CHAPTER

In M1-5A or M1-5B Districts, the Board of Standards and Appeals may permit theaters for a term not to exceed five years, provided that the following findings are made:

(a)        that such use will not impair the character or the future use or development of the surrounding residential or mixed use neighborhoods;

(b)        that such use will not cause undue congestion in local streets; and

(c)        that such use provides a waiting area of adequate size to prevent obstruction of street areas and other uses within the same or other building.

The Board shall prescribe appropriate controls to minimize adverse effects on the character of the surrounding area, including, but not limited to, location of entrances and operable windows; provision of sound-lock vestibules; specification of acoustical insulation; maximum size of establishment; number, kinds of amplification of musical instruments or voices; shielding of flood lights; adequate screening; curb cuts, or parking.

Related Code Sections


1615.1.3 Structural Design, Design Spectral Response Acceleration Parameters
                    (Equation 16-40) where: S D1 = (2/3) S M1 ...
NYC Building Code 2008 > 16 Structural Design > 1615 Earthquake Loads — Site Ground Motion > 1615.1 General Procedure for Determining Maximum Considered Earthquake and Design Spectral Response Accelerations > 1615.1.3 Design Spectral Response Acceleration Parameters
1613.5.4 Structural Design, Design Spectral Response Acceleration Parameters
as determined in Section 1613.5.3. S M1 = The MCE R spectral response accelerations for 1-second period as determined in Section 1613.5.3 ...
NYC Building Code 2014 > 16 Structural Design > 1613 Earthquake Loads > 1613.5 Seismic Ground Motion Values > 1613.5.4 Design Spectral Response Acceleration Parameters
Article 8 Materials, Loads and Stresses [PDF] (page 20)
to M 2 M Cb = 1.75 − 1.05 (M1 ) + 0.3 (M1 ) , but not more than 2.3 2 2 When the bending moment at any point within an unbraced length is larger ...
NYC 1938 Code [PDF] > 8 Materials, Loads and Stresses
1620.4.5 Structural Design, Building Separations
on the same property shall be separated by at least δ MT where δMT = √( δ M1 ) 2 + ( δ M2 ) 2 ...
NYC Building Code 2008 > 16 Structural Design > 1620 Earthquake Loads — Design, Detailing Requirements and Structural Component Load Effects > 1620.4 Seismic Design Category D > 1620.4.5 Building Separations
Article 8 Materials, Loads and Stresses [PDF] (page 21)
their supports in the plane of bending. M Cm = 0.6 + 0.4M1 , but not less than 0.4 2 where M1 / M2 is the ratio of the smaller to larger moments ...
NYC 1938 Code [PDF] > 8 Materials, Loads and Stresses
Help Contact Us Privacy Terms
Code Calculators
Code Calculators
Code calculators automatically generate a detailed list of requirements.
Code Compare
Code Compare
Highlight differences between any two building codes.
Code diagrams
Code diagrams
Unpack the code through illustrations and descriptions.
Shared projects
Shared projects
Projects provide a dedicated space to collaborate on code research.
Code sheet exports
Code sheet exports
Generate a code sheet that integrates with your drawing set.
Search
Search
Don't miss relevant code. Quickly locate sections across your jurisdiction.
UpCodes Premium
Leverage the most sophisticated code compliance platform.
TRY FREE FOR TWO WEEKS VISIT PRICING
UpCodes Premium
Leverage the full code compliance platform.
START 2 WEEK FREE TRIAL LEARN MORE