R505.1.2 In-Line Framing
Go To Full Code Chapter
Where supported by cold-formed steel-framed walls in accordance with Section R603, cold-formed steel floor framing shall be constructed with floor joists located in-line with load-bearing studs located below the joists in accordance with the tolerances specified in AISI S240, Section B1.2.3.
Related Code Sections
R505.1.2 Floors, In-Line Framing
Where supported by cold-formed steel-framed walls in accordance with Section R603, cold-formed steel floor framing shall be constructed with floor ...
R603.1.2 Wall Construction, In-Line Framing
Load-bearing cold-formed steel studs constructed in accordance with Section R603 shall be located in-line with joists, trusses and rafters ...
R804.1.2 Roof-Ceiling Construction, In-Line Framing
Cold-formed steel roof framing constructed in accordance with Section R804 shall be located in line with the tolerances specified in AISI S240 ...
2308.6.8.2 Wood, Floor and Roof Diaphragm Support in Seismic Design Categories D and E
In structures assigned to Seismic Design Categories D or E, floor and roof diaphragms shall be laterally supported by braced wall lines on all edges ...
Building Code of the Department of Personnel & Administration/Office of the State Architect (DPA/OSA) > 23 Wood > 2308 Conventional Light-Frame Construction > 2308.6 Wall Bracing > 2308.6.8 Braced Wall Line and Diaphragm Support > 2308.6.8.2 Floor and Roof Diaphragm Support in Seismic Design Categories D and E