• Codes
  • Features

    Features Overview

    Go to features
    Reference

    Reference.

    A reliable and up-to-date source of codes.
    Research

    Research.

    Rapidly and efficiently calculate project parameters.
    Collaboration

    Collaboration.

    Get everyone on the same page and streamline code research.
    Workflows
    Architects
    Architects
    General Contractors
    General Contractors
    Building Official & Plans Examiners
    Building Official & Plans Examiners
    Inspectors
    Inspectors
    Owners
    Owners
    Subcontractors
    Subcontractors
    Code Consultants
    Code Consultants
  • Pricing
  • Login
  • Sign Up
Sign Up
Login
  • Code Library
  • Features
  • Pricing
  • About
  • Careers
  • Help
  • Contact
  • Terms
  • Privacy
Sign Up
Upgrade to Premium
Code calculators: Code Calculators automatically generates a detailed list of requirements.
REFERENCE
Amendment Styling
Industry-leading search
Code diagrams
RESEARCH
Code calculators
Filter by topic
Code compare
Code sheet exports
COLLABORATION
Team projects
Bookmarks
Comments
START 2 WEEK FREE TRIAL
Have an account? Sign in
// CODE SNIPPET

1105.4 Illumination and Service Receptacles

Uniform Mechanical Code 2018 of Nevada > 11 Refrigeration > 1105.0 General Requirements > 1105.4 Illumination and Service Receptacles
JUMP TO FULL CODE CHAPTER
In addition to the requirements of Section 301.4, permanent lighting fixtures shall be installed for equipment required by this code to be accessible or readily accessible. Such fixtures shall provide illumination to perform the required tasks for which access is provided. Control of the illumination source shall be provided at the access entrance.
Exceptions:
  1. Lighting fixtures shall be permitted to be omitted where the fixed lighting of the building will provide the required illumination.
  2. Equipment located on the roof or on the exterior walls of a building.

Related Code Sections


1105.4 Refrigeration, Illumination and Service Receptacles
or readily accessible. Such fixtures shall provide illumination to perform the required tasks for which access is provided. Control ...
Uniform Mechanical Code 2018 of Nevada > 11 Refrigeration > 1105.0 General Requirements > 1105.4 Illumination and Service Receptacles
E3405.6 General Requirements, Illumination
Artificial illumination shall be provided for all working spaces for service equipment and panelboards installed indoors and shall not be controlled ...
Residential Code 2012 of Nevada > 34 General Requirements > E3405 Equipment Location and Clearances > E3405.6 Illumination
E3405.7 General Requirements, Illumination
Artificial illumination shall be provided for all working spaces for service equipment and panelboards installed indoors and shall not be controlled ...
Residential Code 2018 of Nevada > 34 General Requirements > E3405 Equipment Location and Clearances > E3405.7 Illumination
(D) General, Illumination
Illumination shall be provided for all working spaces about service equipment, switchboards, switchgear, panelboards, or motor control centers ...
National Electrical Code 2017 of Nevada > 1 General > 110 Requirements for Electrical Installations > 110.26 Spaces About Electrical Equipment > (D) Illumination
(C) Special Occupancies, Illumination
in unclassified locations. Such fixtures shall be serviced from outside the spray area. [ 33: 6.6.1] Luminaires, like that shown in Figure 516.6(C ...
National Electrical Code 2017 of Nevada > 5 Special Occupancies > 516 Spray Application, Dipping, Coating, and Printing Processes Using Flammable or Combustible Materials > 516.6 Wiring and Equipment in Class I Locations > (C) Illumination
Help Contact Us Privacy Terms
Search
Search
Don't miss relevant code. Quickly locate sections across your jurisdiction.
Code Compare
Code Compare
Highlight differences between any two building codes.
Code Calculators
Code Calculators
Code calculators automatically generate a detailed list of requirements.
Code sheet exports
Code sheet exports
Generate a code sheet that integrates with your drawing set.
Shared projects
Shared projects
Projects provide a dedicated space to collaborate on code research.
Code diagrams
Code diagrams
Unpack the code through illustrations and descriptions.
UpCodes Premium
Leverage the most sophisticated code compliance platform.
VISIT PRICING
UpCodes Premium
Leverage the full code compliance platform.
START 2 WEEK FREE TRIAL PRICING