• Codes
  • Features

    Features Overview

    Go to features
    Reference

    Reference.

    A reliable and up-to-date source of codes.
    Research

    Research.

    Rapidly and efficiently calculate project parameters.
    Collaboration

    Collaboration.

    Get everyone on the same page and streamline code research.
    Workflows
    Architects General Contractor Building Official & Plans Examiner Inspectors Owner Subcontractors Code Consultants
  • Pricing
  • Login
  • Sign Up
Sign Up
Login
  • Code Library
  • Features
  • Pricing
  • About
  • Careers
  • Help
  • Contact
  • Terms
  • Privacy
Sign Up
Upgrade to Premium
Code calculators: Code Calculators automatically generates a detailed list of requirements.
REFERENCE
Amendment Styling
Industry-leading search
Suggested code sections
Code diagrams
RESEARCH
Code calculators
Filter by topic
Code compare
Code sheet exports
COLLABORATION
Team projects
Bookmarks
Comments
START 2 WEEK FREE TRIAL
Have an account? Sign in
// CODE SNIPPET

1926.1431(r)(3) If Using a Marine-Hoisted Personnel Transfer Device:

OSHA 1926 Construction > CC Cranes & Derricks in Construction > 1926.1431 Hoisting Personnel > 1926.1431(r) Hoisting Personnel for Marine Transfer > 1926.1431(r)(3) If Using a Marine-Hoisted Personnel Transfer Device:
JUMP TO FULL CODE CHAPTER

1926.1431(r)(3)(i)

The following paragraphs of this section apply: (a), (c)(2), (d)(1), (d)(3), (d)(4), (e)(1) through (5), (e)(12), (f)(1), (g), (h), (j), (k)(1), (k)(8), (k)(9), (k)(10)(ii), (k)(11)(i), (k)(12), (m), and (n). Where the terms "personnel platform" or "platform" are used in these paragraphs, substitute them with "marine-hoisted personnel transfer device."

1926.1431(r)(3)(iii)

The number of workers occupying the transfer device must not exceed the maximum number it was designed to hold.

1926.1431(r)(3)(iv)

Each employee must wear a U.S. Coast Guard personal flotation device approved for industrial use.

1926.1431(r)(3)(ii)

The transfer device must be used only for transferring workers.

Related Code Sections


1926.1431(r)(3) Cranes & Derricks in Construction, If Using a Marine-Hoisted Personnel Transfer Device:
, substitute them with "marine-hoisted personnel transfer device ...
OSHA 1926 Construction > CC Cranes & Derricks in Construction > 1926.1431 Hoisting Personnel > 1926.1431(r) Hoisting Personnel for Marine Transfer > 1926.1431(r)(3) If Using a Marine-Hoisted Personnel Transfer Device:
1926.1431 Cranes & Derricks in Construction, Hoisting Personnel
"personnel platform" or "platform" are used in these paragraphs, substitute them with "marine-hoisted personnel transfer device ...
OSHA 1926 Construction > CC Cranes & Derricks in Construction > 1926.1431 Hoisting Personnel
1926.1431(b) Cranes & Derricks in Construction, Use of Personnel Platform
). Solely for transfer to or from a marine worksite in a marine-hoisted personnel ...
OSHA 1926 Construction > CC Cranes & Derricks in Construction > 1926.1431 Hoisting Personnel > 1926.1431(b) Use of Personnel Platform
1926.1431(b)(2)(iii) Cranes & Derricks in Construction,
Solely for transfer to or from a marine worksite in a marine-hoisted personnel transfer device ( see paragraph (r) of this section for requirements ...
OSHA 1926 Construction > CC Cranes & Derricks in Construction > 1926.1431 Hoisting Personnel > 1926.1431(b) Use of Personnel Platform > 1926.1431(b)(2) Exceptions: > 1926.1431(b)(2)(iii)
1926.1431(r)(2) Cranes & Derricks in Construction,
If using a personnel platform, paragraphs (a) through (n) of this section apply ...
OSHA 1926 Construction > CC Cranes & Derricks in Construction > 1926.1431 Hoisting Personnel > 1926.1431(r) Hoisting Personnel for Marine Transfer > 1926.1431(r)(2)
Help Contact Us Privacy Terms
Code Compare
Code Compare
Highlight differences between any two building codes.
Code diagrams
Code diagrams
Unpack the code through illustrations and descriptions.
Code sheet exports
Code sheet exports
Generate a code sheet that integrates with your drawing set.
Code Calculators
Code Calculators
Code calculators automatically generate a detailed list of requirements.
Shared projects
Shared projects
Projects provide a dedicated space to collaborate on code research.
Search
Search
Don't miss relevant code. Quickly locate sections across your jurisdiction.
View thousands of relevant UL Certified products and assemblies that help achieve code compliance
View thousands of relevant UL Certified products and assemblies that help achieve code compliance
Access to UL product and system certification information.
UpCodes Premium
Leverage the most sophisticated code compliance platform.
TRY FREE FOR TWO WEEKS VISIT PRICING
Join the waitlist
We are looking to gauge the level of interest in linking UL product and system certification information alongside related code sections.

Let us know your email and we’ll ping you once it’s ready! Learn more.

Thank you for your interest!

If you’re open to it, we would love to jump on the phone to make sure we’re building this in the best way possible for your workflow. Any insight or advice would be greatly appreciated. We’ve sent you an email with a calendar link to book at time with us.


Cancel
Get Early Access
UpCodes Premium
Leverage the full code compliance platform.
START 2 WEEK FREE TRIAL LEARN MORE