608.8.2.3 Identification Tape
JUMP TO FULL CODE CHAPTER
Where used, identification tape shall be at least 3 inches (76 mm) wide and have white or black lettering on a purple field stating "CAUTION: NONPOTABLE WATER — DO NOT DRINK." Identification tape shall be installed on top of nonpotable rainwater distribution pipes, fastened at least every 10 feet (3048 mm) to each pipe length and run continuously the entire length of the pipe.
Related Code Sections
608.8.2.3 Water Supply and Distribution, Identification Tape
Where used, identification tape shall be at least 3 inches (76 mm) wide and have white or black lettering on a purple field stating "CAUTION ...
2017 FBC - Plumbing, 6th edition > 6 Water Supply and Distribution > 608 Protection of Potable Water Supply > 608.8 Identification of Nonpotable Water Systems > 608.8.2 Distribution Pipe Labeling and Marking > 608.8.2.3 Identification Tape
608.9.2.3 Water Supply and Distribution, Identification Tape
Where used, identification tape shall be at least 3 inches (76 mm) wide and have white or black lettering on a purple field stating "CAUTION ...
2020 FBC - Plumbing, 7th edition > 6 Water Supply and Distribution > 608 Protection of Potable Water Supply > 608.9 Identification of Nonpotable Water Systems > 608.9.2 Distribution Pipe Labeling and Marking > 608.9.2.3 Identification Tape
P2901.2.2.3 Water Supply and Distribution, Identification Tape
Where used, identification tape shall be not less than 3 inches (76 mm) wide and have white or black lettering on a purple field stating "CAUTION ...
2017 FBC - Residential, 6th edition > 29 Water Supply and Distribution > P2901 General > P2901.2 Identification of Nonpotable Water Systems > P2901.2.2 Distribution Pipe Labeling and Marking > P2901.2.2.3 Identification Tape
P2901.2.2.3 Water Supply and Distribution, Identification Tape
Where used, identification tape shall be not less than 3 inches (76 mm) wide and have white or black lettering on a purple field stating "CAUTION ...
2020 FBC - Residential, 7th edition > 29 Water Supply and Distribution > P2901 General > P2901.2 Identification of Nonpotable Water Systems > P2901.2.2 Distribution Pipe Labeling and Marking > P2901.2.2.3 Identification Tape
608.9 Water Supply and Distribution, Identification of Nonpotable Water Systems
tape or wrap. Pipe identification shall include the contents of the piping system and an arrow indicating the direction of flow. Hazardous piping ...
2020 FBC - Plumbing, 7th edition > 6 Water Supply and Distribution > 608 Protection of Potable Water Supply > 608.9 Identification of Nonpotable Water Systems