• Codes
  • Features

    Features Overview

    Go to features
    Reference

    Reference.

    A reliable and up-to-date source of codes.
    Research

    Research.

    Rapidly and efficiently calculate project parameters.
    Collaboration

    Collaboration.

    Get everyone on the same page and streamline code research.
    Workflows
    Architects
    Architects
    General Contractors
    General Contractors
    Building Official & Plans Examiners
    Building Official & Plans Examiners
    Inspectors
    Inspectors
    Owners
    Owners
    Subcontractors
    Subcontractors
    Code Consultants
    Code Consultants
  • Pricing
  • Login
  • Sign Up
Sign Up
Login
  • Code Library
  • Features
  • Pricing
  • About
  • Careers
  • Help
  • Contact
  • Terms
  • Privacy
Sign Up
Upgrade to Premium
Code calculators: Code Calculators automatically generates a detailed list of requirements.
REFERENCE
Amendment Styling
Industry-leading search
Code diagrams
RESEARCH
Code calculators
Filter by topic
Code compare
Code sheet exports
COLLABORATION
Team projects
Bookmarks
Comments
START 2 WEEK FREE TRIAL
Have an account? Sign in
// CODE SNIPPET

R308.1.1 Identification of Multiple Assemblies

Residential Code 2021 of Colorado > 3 Building Planning > R308 Glazing > R308.1 Identification > R308.1.1 Identification of Multiple Assemblies
JUMP TO FULL CODE CHAPTER
Multipane assemblies having individual panes not exceeding 1 square foot (0.09 m2) in exposed area shall have not less than one pane in the assembly identified in accordance with Section R308.1. Other panes in the assembly shall be labeled "CPSC 16 CFR 1201" or "ANSI Z97.1" as appropriate.

Related Code Sections


R308.1.1 Building Planning, Identification of Multiple Assemblies
Multipane assemblies having individual panes not exceeding 1 square foot (0.09 m2) in exposed area shall have not less than one pane in the assembly ...
Residential Code 2021 of Colorado > 3 Building Planning > R308 Glazing > R308.1 Identification > R308.1.1 Identification of Multiple Assemblies
802.8.2 Special Rooms and Spaces, Identification
Each designated aisle seat shall be identified by the International Symbol of Accessibility ...
Accessible and Usable Buildings and Facilities 2009 of Colorado > 8 Special Rooms and Spaces > 802 Assembly Areas > 802.8 Designated Aisle Seats > 802.8.2 Identification
802.8.2 Special Rooms and Spaces, Identification
Each designated aisle seat shall be identified by a sign or marker ...
Accessible and Usable Buildings and Facilities 2017 of Colorado > 8 Special Rooms and Spaces > 802 Assembly Areas > 802.8 Designated Aisle Seats > 802.8.2 Identification
R904.4 Roof Assemblies, Product Identification
Roof covering materials shall be delivered in packages bearing the manufacturer's identifying marks and approved testing agency labels required. Bulk ...
Residential Code 2021 of Colorado > 9 Roof Assemblies > R904 Materials > R904.4 Product Identification
722.5.1.3.2 Fire and Smoke Protection Features, Identification
Sprayed fire-resistant materials shall be identified by density and thickness required for a given fire-resistance rating ...
Building Code 2021 of Colorado > 7 Fire and Smoke Protection Features > 722 Calculated Fire Resistance > 722.5 Steel Assemblies > 722.5.1 Structural Steel Columns > 722.5.1.3 Sprayed Fire-Resistant Materials > 722.5.1.3.2 Identification
Help Contact Us Privacy Terms
Search
Search
Don't miss relevant code. Quickly locate sections across your jurisdiction.
Code Compare
Code Compare
Highlight differences between any two building codes.
Shared projects
Shared projects
Projects provide a dedicated space to collaborate on code research.
Code diagrams
Code diagrams
Unpack the code through illustrations and descriptions.
Code Calculators
Code Calculators
Code calculators automatically generate a detailed list of requirements.
Code sheet exports
Code sheet exports
Generate a code sheet that integrates with your drawing set.
UpCodes Premium
Leverage the most sophisticated code compliance platform.
TRY FREE FOR TWO WEEKS VISIT PRICING
UpCodes Premium
Leverage the full code compliance platform.
START 2 WEEK FREE TRIAL PRICING