2.12.4.3 Identification Marking
Safety Code for Elevators and Escalators 2019 of Illinois > 2 Electric Elevators > 2.12 Hoistway Door Locking Devices and Closed Detection Means, and Hoistway Access Switches > 2.12.4 Listing/Certification of Door Locking Devices and Door or Gate Closed Detection Means > 2.12.4.3 Identification Marking
Go To Full Code Chapter
Each listed/certified device shall be labeled. The label shall be permanently attached to the device and shall be located to be readily visible when the device is installed in its operating position (see 2.26.4.3.2 for additional marking requirements for S1L rated devices).
The label shall include the following data:
(a) the name, trademark, or certifying organization file number by which the organization that manufactured the product can be identified
(b) the certifying organization name or identifying symbol
(c) statement of compliance with ASME A17.1/CSAB44
(d) a distinctive type, model, or style letter or number
(e) the rated voltage and current, and whether alternating current (AC) or direct current (DC)
(f) rated test force and rated test movement when the device is a type released by an interlock retiring cam (see 8.3.3.47)
(h) if the device has only been type tested and listed/certified for use on a private residence elevator, the label shall indicate the restricted use
Related Code Sections
2.12.4.3 Electric Elevators, Identification Marking
the device is installed in its operating position (see 2.26.4.3.2 for additional marking requirements for S1L rated devices). The label shall include ...
Safety Code for Elevators and Escalators 2019 of Illinois > 2 Electric Elevators > 2.12 Hoistway Door Locking Devices and Closed Detection Means, and Hoistway Access Switches > 2.12.4 Listing/Certification of Door Locking Devices and Door or Gate Closed Detection Means > 2.12.4.3 Identification Marking
703.5 Fire and Smoke Protection Features, Marking and Identification
in the concealed space. Such identification shall: Be located within 15 feet (4572 mm) of the end of each wall and at intervals not exceeding 30 ...
703.7 Fire and Smoke Protection Features, Marking and Identification
in the concealed space. Such identification shall: Be located within 15 feet (4572 mm) of the end of each wall and at intervals not exceeding 30 ...
909.14 Fire Protection and Life Safety Systems, Marking and Identification
The detection and control systems shall be clearly marked at all junctions, accesses and terminations ...
909.14 Fire Protection and Life Safety Systems, Marking and Identification
The detection and control systems shall be clearly marked at all junctions, accesses and terminations ...