• Codes
  • Features

    Features Overview

    Go to features
    Reference

    Reference.

    A reliable and up-to-date source of codes.
    Research

    Research.

    Rapidly and efficiently calculate project parameters.
    Collaboration

    Collaboration.

    Get everyone on the same page and streamline code research.
    Workflows
    Architects
    Architects
    General Contractors
    General Contractors
    Building Official & Plans Examiners
    Building Official & Plans Examiners
    Inspectors
    Inspectors
    Owners
    Owners
    Subcontractors
    Subcontractors
    Code Consultants
    Code Consultants
  • Pricing
  • Login
  • Sign Up
Sign Up
Login
  • Code Library
  • Features
  • Pricing
  • About
  • Careers
  • Help
  • Contact
  • Terms
  • Privacy
Sign Up
Upgrade to Premium
Code calculators: Code Calculators automatically generates a detailed list of requirements.
REFERENCE
Amendment Styling
Industry-leading search
Code diagrams
RESEARCH
Code calculators
Filter by topic
Code compare
Code sheet exports
COLLABORATION
Team projects
Bookmarks
Comments
START 2 WEEK FREE TRIAL
Have an account? Sign in
// CODE SNIPPET

1215.0 Hydronic Space Heating

Uniform Mechanical Code 2018 of Nevada > 12 Hydronics > 1215.0 Hydronic Space Heating
JUMP TO FULL CODE CHAPTER

1215.1 General

Based on the system design, the heat-distribution units shall be selected in accordance with the manufacturer's specifications.

1215.2 Installation

Heat-distribution units shall be installed in accordance with the manufacturer's installation instructions and this code.

1215.3 Freeze Protection

Hydronic systems and components shall be designed, installed, and protected from freezing.

1215.4 Balancing

System loops shall be installed so that the design flow rates are achieved within the system.

1215.5 Heat Transfer Fluid

The ignitable flash point of heat transfer fluid in a hydronic piping system shall be a minimum of 50°F (28°C) above the maximum system operating temperature. The heat transfer fluid shall be compatible with the makeup fluid supplied to the system.

Related Code Sections


1215.0 Hydronics, Hydronic Space Heating
The ignitable flash point of heat transfer fluid in a hydronic ...
Uniform Mechanical Code 2018 of Nevada > 12 Hydronics > 1215.0 Hydronic Space Heating
G2413.2 Fuel Gas, (402.2) Maximum Gas Demand
APPLIANCES APPLIANCE INPUT BTU/H (Approx.) Space Heating Units   Hydronic boiler   Single family 100,000 ...
Residential Code 2012 of Nevada > 24 Fuel Gas > G2413 (402) Pipe Sizing > G2413.2 (402.2) Maximum Gas Demand
1207.0 Hydronics, Heating Appliances and Equipment
Heating appliances, equipment, safety and operational controls shall be listed for its intended use in a hydronic heating system and installed ...
Uniform Mechanical Code 2018 of Nevada > 12 Hydronics > 1207.0 Heating Appliances and Equipment
E 503.5.12 Sustainable Practices, Radiant Heating Systems
Radiant heating shall be used when heating is required for unenclosed spaces. Exception: Loading docks equipped with air curtains. [ASHRAE 90.1 ...
Uniform Mechanical Code 2018 of Nevada > E Sustainable Practices > E 503.0 Heating, Ventilation, and Air-Conditioning — Other Than Low-Rise Residential Buildings > E 503.5 Prescriptive Path, Economizers > E 503.5.12 Radiant Heating Systems
E 503.5.12.1 Sustainable Practices, Heating Enclosed Spaces
Radiant heating systems that are used as primary or supplemental enclosed space heating shall be in accordance with this appendix, including ...
Uniform Mechanical Code 2018 of Nevada > E Sustainable Practices > E 503.0 Heating, Ventilation, and Air-Conditioning — Other Than Low-Rise Residential Buildings > E 503.5 Prescriptive Path, Economizers > E 503.5.12 Radiant Heating Systems > E 503.5.12.1 Heating Enclosed Spaces
Help Contact Us Privacy Terms
Search
Search
Don't miss relevant code. Quickly locate sections across your jurisdiction.
Code diagrams
Code diagrams
Unpack the code through illustrations and descriptions.
Shared projects
Shared projects
Projects provide a dedicated space to collaborate on code research.
Code sheet exports
Code sheet exports
Generate a code sheet that integrates with your drawing set.
Code Calculators
Code Calculators
Code calculators automatically generate a detailed list of requirements.
Code Compare
Code Compare
Highlight differences between any two building codes.
UpCodes Premium
Leverage the most sophisticated code compliance platform.
VISIT PRICING
UpCodes Premium
Leverage the full code compliance platform.
START 2 WEEK FREE TRIAL PRICING