P-1005.4 House Storm Drains
JUMP TO FULL CODE CHAPTER
House storm drains underground beyond the building wall shall be installed in
accordance with Section P-902.3. These materials shall be installed with appropriate fittings in compliance with
standards in Section P-305.
When installed in filled or unstable ground, the house storm drain shall be of cast iron or
hard temper copper of a weight not less than type "L".
Related Code Sections
P-1005.4 Storm Water Drainage Piping, House Storm Drains
House storm drains underground beyond the building wall shall be installed in
accordance with Section P-902.3. These materials shall be installed ...
Philadelphia Plumbing Code > 10 Storm Water Drainage Piping > P-1005 Materials > P-1005.4 House Storm Drains
P-908.1 Soil and Waste Piping, General
This section shall govern the replacement of existing house drain (including house storm drain)
piping by pipe-bursting methods ...
Philadelphia Plumbing Code > 9 Soil and Waste Piping > P-908 Replacement of Underground Sewers by Pipe-Bursting Methods > P-908.1 General
P-1006.2 Storm Water Drainage Piping, Storm Drains
The minimum size of the house storm drain or any of its branches that drain a roof or area
drain shall be determined according to Table P-1006.1. The ...
Philadelphia Plumbing Code > 10 Storm Water Drainage Piping > P-1006 Size of Leaders and Storm Drains > P-1006.2 Storm Drains
P-501.7 Traps, Cleanouts, Interceptors, and Backwater Valves, House Traps
An approved house trap shall be installed in each sanitary house drain and in each house storm
drain located within the property line of the building ...
Philadelphia Plumbing Code > 5 Traps, Cleanouts, Interceptors, and Backwater Valves > P-501 General Requirements for Traps > P-501.7 House Traps
P-1006.1 Storm Water Drainage Piping, Vertical Leaders
there is a continuous or semi-continuous discharge into the house storm drain,
as from a bilge pump, ejector, air conditioning equipment, or similar device ...
Philadelphia Plumbing Code > 10 Storm Water Drainage Piping > P-1006 Size of Leaders and Storm Drains > P-1006.1 Vertical Leaders