• Codes
  • Features

    Features Overview

    Go to features
    Reference

    Reference.

    A reliable and up-to-date source of codes.
    Research

    Research.

    Rapidly and efficiently calculate project parameters.
    Collaboration

    Collaboration.

    Get everyone on the same page and streamline code research.
    Workflows
    Architects
    Architects
    General Contractors
    General Contractors
    Building Official & Plans Examiners
    Building Official & Plans Examiners
    Inspectors
    Inspectors
    Owners
    Owners
    Subcontractors
    Subcontractors
    Code Consultants
    Code Consultants
  • Pricing
  • Login
  • Sign Up
Sign Up
Login
  • Code Library
  • Features
  • Pricing
  • About
  • Careers
  • Help
  • Contact
  • Terms
  • Privacy
Sign Up
Upgrade to Premium
Code calculators: Code Calculators automatically generates a detailed list of requirements.
REFERENCE
Amendment Styling
Industry-leading search
Code diagrams
RESEARCH
Code calculators
Filter by topic
Code compare
Code sheet exports
COLLABORATION
Team projects
Bookmarks
Comments
START 2 WEEK FREE TRIAL
Have an account? Sign in
// CODE SNIPPET

607.2 Hot Water Supply Temperature Maintenance

Plumbing Code 2009 of Alabama > 6 Water Supply and Distribution > 607 Hot Water Supply System > 607.2 Hot Water Supply Temperature Maintenance
JUMP TO FULL CODE CHAPTER
Where the developed length of hot water piping from the source of hot water supply to the farthest fixture exceeds 100 feet (30 480 mm), the hot water supply system shall be provided with a method of maintaining the temperature in accordance with the International Energy Conservation Code.

607.2.1 Piping Insulation

Circulating hot water system piping shall be insulated in accordance with the International Energy Conservation Code.

607.2.2 Hot Water System Controls

Automatic circulating hot water system pumps or heat trace shall be arranged to be conveniently turned off, automatically or manually, when the hot water system is not in operation.

607.2.3 Recirculating Pump

Where a thermostatic mixing valve is used in a system with a hot water recirculating pump, the hot water or tempered water return line shall be routed to the cold water inlet pipe of the water heater and the cold water inlet pipe or the hot water return connection of the thermostatic mixing valve.

Related Code Sections


607.2 Water Supply and Distribution, Hot Water Supply Temperature Maintenance
Where the developed length of hot water piping from the source of hot water supply to the farthest fixture exceeds 100 feet (30 480 mm), the hot ...
Plumbing Code 2009 of Alabama > 6 Water Supply and Distribution > 607 Hot Water Supply System > 607.2 Hot Water Supply Temperature Maintenance
607.1 Water Supply and Distribution, Where Required
, cleansing, laundry or building maintenance. In nonresidential occupancies , hot water shall be supplied for culinary purposes, cleansing, laundry ...
Plumbing Code 2015 of Alabama > 6 Water Supply and Distribution > 607 Hot Water Supply System > 607.1 Where Required
607.1 Water Supply and Distribution, Where Required
, cleansing, laundry or building maintenance. In nonresidential occupancies , hot water shall be supplied for culinary purposes, cleansing, laundry ...
Plumbing Code 2021 of Alabama > 6 Water Supply and Distribution > 607 Hot Water Supply System > 607.1 Where Required
Section 607 Water Supply and Distribution, Hot Water Supply System
, cleansing, laundry or building maintenance. In nonresidential occupancies , hot water shall be supplied for culinary purposes, cleansing, laundry ...
Plumbing Code 2009 of Alabama > 6 Water Supply and Distribution > 607 Hot Water Supply System
Section 607 Water Supply and Distribution, Hot Water Supply System
, cleansing, laundry or building maintenance. In nonresidential occupancies , hot water shall be supplied for culinary purposes, cleansing, laundry ...
Plumbing Code 2021 of Alabama > 6 Water Supply and Distribution > 607 Hot Water Supply System
Help Contact Us Privacy Terms
Code Compare
Code Compare
Highlight differences between any two building codes.
Code Calculators
Code Calculators
Code calculators automatically generate a detailed list of requirements.
Code sheet exports
Code sheet exports
Generate a code sheet that integrates with your drawing set.
Search
Search
Don't miss relevant code. Quickly locate sections across your jurisdiction.
Shared projects
Shared projects
Projects provide a dedicated space to collaborate on code research.
Code diagrams
Code diagrams
Unpack the code through illustrations and descriptions.
UpCodes Premium
Leverage the most sophisticated code compliance platform.
VISIT PRICING
UpCodes Premium
Leverage the full code compliance platform.
START 2 WEEK FREE TRIAL PRICING