223.2 Hospitals, Rehabilitation Facilities, Psychiatric Facilities and Detoxification Facilities
Go To Full Code Chapter
Hospitals, rehabilitation facilities, psychiatric facilities and detoxification facilities shall comply with 223.2.
223.2.1 Facilities Not Specializing in Treating Conditions That Affect Mobility
In facilities not specializing in treating conditions that affect mobility, at least 10 percent, but no fewer than one, of the patient sleeping rooms shall provide mobility features complying with 805.
Note to Reader: The Department of Justice's ADA standards also require the following:
Medical care facilities. Medical care facilities that are subject to this part [of the title III regulation or to this section of the title II regulation] shall comply with the provisions of the 2010 Standards applicable to medical care facilities, including, but not limited to, sections 223 and 805. In addition, medical care facilities that do not specialize in the treatment of conditions that affect mobility shall disperse the accessible patient bedrooms required by section 223.2.1 of the 2010 Standards in a manner that is proportionate by type of medical specialty.
223.2.2 Facilities Specializing in Treating Conditions That Affect Mobility
In facilities specializing in treating conditions that affect mobility, 100 percent of the patient sleeping rooms shall provide mobility features complying with 805.
Advisory 223.2.2 Facilities Specializing in Treating Conditions That Affect Mobility. Conditions that affect mobility include conditions requiring the use or assistance of a brace, cane, crutch, prosthetic device, wheelchair, or powered mobility aid; arthritic, neurological, or orthopedic conditions that severely limit one's ability to walk; respiratory diseases and other conditions which may require the use of portable oxygen; and cardiac conditions that impose significant functional limitations. Facilities that may provide treatment for, but that do not specialize in treatment of such conditions, such as general rehabilitation hospitals, are not subject to this requirement but are subject to Section 223.2.1.
Upcodes Diagrams
Related Code Sections
223.2 Scoping Requirements, Hospitals, Rehabilitation Facilities, Psychiatric Facilities and Detoxification Facilities
Hospitals, rehabilitation facilities, psychiatric facilities and detoxification facilities shall comply with 223.2 ...
208.2.2 Scoping Requirements, Rehabilitation Facilities and Outpatient Physical Therapy Facilities
Twenty percent of patient and visitor parking spaces provided to serve rehabilitation facilities specializing in treating conditions that affect ...
232.3 Scoping Requirements, Special Holding Cells and Special Housing Cells
, administrative or disciplinary detention or segregation, detoxification, and medical isolation.
EXCEPTION: Alterations to cells shall not be required ...
232 Scoping Requirements, Detention Facilities and Correctional Facilities
Buildings, facilities, or portions thereof, in which people are detained for penal or correction purposes, or in which the liberty of the inmates ...
233 Scoping Requirements, Residential Facilities
Facilities with residential dwelling units shall comply with 233. Advisory 233.1 General. Section 233 outlines the requirements ...